MFC SERIES
UP TO 30 WATTS
FILTERED CONFIGURABLE DC/DC CONVERTERS
5 Watt Dual Output Modules
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
DUAL OUTPUT MODULES
05D
12D
TYP
15D
TYP
PARAMETER
CONDITIONS
MIN
4.95
4.9
TYP
5.00
5.0
MAX
5.05
5.1
MIN
MAX
12.12
12.24
MIN
MAX
UNITS
OUTPUT VOLTAGE
+V
11.88 12.00
11.76 12.00
14.85 15.00 15.15
14.70 15.00 15.30
OUT
VDC
–V
OUT
1
OUTPUT CURRENT
V
= 16 to 40 VDC
IN
Tc = –55°C to +125°C
—
500
800
—
208
333
—
167
267
mA
1
OUTPUT POWER
V
= 16 to 40 VDC
IN
Tc = –55°C to +125°C
—
—
—
—
5
—
—
—
5
—
—
—
5
W
OUTPUT RIPPLE VOLT.
10 kHz - 2 MHz
150
40
140
60
150
mV p-p
LINE REGULATION
Vin = 16 to 40 VDC
Tc = –55°C to +125°C
+V
—
—
10
40
25
75
—
—
10
40
50
—
—
10
40
50
OUT
mV
mV
–V
180
180
OUT
LOAD REGULATION
NO LOAD TO FULL
Tc = –55°C to +125°C
+V
—
—
10
50
50
—
—
10
50
50
—
—
10
50
50
OUT
–V
200
200
200
OUT
2
CROSS REGULATION
+P = 20 - 80 %, –P = 80 - 20%
O
O
—
—
10
5
20
8
—
—
8
15
6
—
—
7
3
15
6
–P = 20 - 80 %, +P = 80 - 20%
O
O
%
+P = 50 - 10 %, –P = 50%
O
O
3.7
–P = 50 - 10 %, +P = 50%
O
O
NO LOAD TO FULL
˜CONTINUOUS
INPUT VOLTAGE
Tc = –55°C to +125°
16
28
40
16
28
40
16
28
40
VDC
V
TRANSIENT 50 msec
NO LOAD
—
—
—
50
35
—
—
—
50
58
—
—
—
50
60
INPUT CURRENT
30
33
38
Tc = –55°C to +125°C
FULL LOAD
INHIBITED
—
—
—
—
68
248
3
—
5
—
—
—
—
69
235
3
—
4
—
—
—
—
70
235
3
—
4
mA
INPUT RIPPLE
CURRENT
10 kHz TO 10 MHz
Tc = –55°C to +125°C
25
30
72
80
160
—
25
30
75
100
150
—
25
30
75
100
150
—
mA p-p
%
EFFICIENCY
3, 4
LOAD FAULT
POWER DISSIPATION
SHORT CIRCUIT
—
—
1.3
1.8
50
—
—
1.3
1
1.7
10
—
—
1.3
1
1.6
10
W
RECOVERY
50% - 100% - 50% BALANCED
TRANSIENT
—
ms
STEP LOAD
4, 5
RESPONSE
—
—
—
—
150
100
—
—
300
200
750
500
—
—
300
500
750
mV
µs
RECOVERY
1250
4, 5
STEP LINE RESP.
16 TO 40 VDC
—
—
—
—
—
—
—
—
—
—
—
—
750
500
—
—
—
—
—
—
50
50
150
400
3
125
125
375
1000
10
—
—
—
—
—
—
150
100
250
800
3
375
250
625
2000
10
mV pk
µs
TRANSIENT
40 TO 16 VDC
16 TO 40 VDC
1200
1200
25
RECOVERY
40 TO 16 VDC
START-UP
DELAY
ms
OVERSHOOT
500
0
120
0
150
mV pk
Notes
1. Up to 4 watts (80% full power) is available from either output providing the
opposite output is carrying 20% of total power.
3. Indefinite short circuit protection not guaranteed above 100°C (case).
4. Recovery time is measured from application of the transient to point at which
2. Shows regulation effect on the minus output during the defined cross loading
conditions. See Figures 15 and 16.
V
is within 1% of V at final value.
OUT
OUT
5. Transition time >10µs.
10