MD600xRWSeries
2:1 Input, 6W SIP,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 6W Output Power
Conditions
Min.
4.5
9.0
Typ.
5.0
12.0
24.0
48.0
30
Max.
9.0
18.0
36.0
75.0
Units
5 VDC Input
12 VDC Input
24 VDC Input 18.0
48 VDC Input 36.0
• Miniature SIP Case
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• 36 Standard Models
• Short Circuit Protected
• -40°C to +65°C Operation
• Single & Dual Outputs
• Industry Standard Pin-Out
Input Voltage Range
VDC
Input Reflected Ripple Current
Start Up Time
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
mA P - P
mS
See Note 1
30
Capacitor Filter
Conditions
Min.
Typ.
1.0
Max.
Units
%
%
%
%
mV P - P
mSec
%
VIN = Min to Max
IOUT = 0% to 100%
See Note 2
0.2
1.0
5.0
75
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
See Note 3
0.5
See Note 4
3.0
0.02
%/°C
Continuous (Autorecovery)
Parameter
Isolation Voltage
Conditions
Min.
60 Seconds 1,500
1.0
Typ.
Max.
Units
VDC
G
pF
kHz
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
50
100
Standard
Level
Radiated Emissions
Conducted Emissions
EN 55022
EN 55022
Class A
Class A
See Note 4 Pg 3
Criteria A; 8 kV Air
Criteria A; 6 kV Contact
Criteria A; 10V/m
ESD
EN 61000-4-2
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
See Note 6 Pg 3
See Note 6 Pg 3
Criteria A; 2 kV
Criteria A; 1 kV
Criteria A; 10 Vrms
Criteria A; 1A/m
PFMF
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+65
+105
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-55
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
See Mechanical Drawing (Page 4)
Non-Conductive Black Plastic (UL94-V0)
0.166 Oz (4.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
770
Typ.
Typ.
Max.
Units
kHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
5 VDC Input
Min.
Max.
15.0
25.0
50.0
100.0
260
Units
VDC
°C
12 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com