MCC 310
MCD 310
ITRMS = 2x 500 A
ITAVM = 2x 320 A
VRRM = 800-2200 V
Thyristor Modules
Thyristor/Diode Modules
3
7
2
6
VRSM
VDSM
VRRM
VDRM
Type
5
4
1
V
V
Version 1
Version 1
900
1300
1500
1700
1900
800
1200
1400
1600
1800
MCC 310-08io1
MCC 310-12io1
MCC 310-14io1
MCC 310-16io1
MCC 310-18io1
MCD 310-08io1
MCD 310-12io1
MCD 310-14io1
MCD 310-16io1
MCD 310-18io1
3
3
6 7 1
5 4 2
Symbol
Test Conditions
Maximum Ratings
MCC
MCD
ITRMS, IFRMS
TVJ = TVJM
TC = 85°C; 180° sine
500
320
A
A
ITAVM FAVM
, I
1
5 4 2
ITSM, IFSM
TVJ = 45°C;
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
9200
9800
A
A
T
VJ = TVJM
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
8000
8600
A
A
VR = 0
òi2dt
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
420 000
400 000
A2s
A2s
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
320 000
306 000
A2s
A2s
Features
●
International standard package
Direct copper bonded Al2O3 -ceramic
base plate
Planar passivated chips
Isolation voltage 3600 V~
UL registered, E 72873
Keyed gate/cathode twin pins
(di/dt)cr
TVJ = TVJM
repetitive, IT = 960 A
100
A/ms
●
f =50 Hz, tP =200 ms
VD = 2/3 VDRM
IG = 1 A
●
●
●
●
non repetitive, IT = 320 A
VDR = 2/3 VDRM
500
A/ms
V/ms
diG/dt = 1 A/ms
(dv/dt)cr
PGM
TVJ = TVJM
;
1000
RGK = ¥; method 1 (linear voltage rise)
Applications
Motor control
Power converter
Heat and temperature control for
industrial furnaces and chemical
processes
Lighting control
TVJ = TVJM
IT = ITAVM
tP = 30 ms
tP = 500 ms
120
60
W
W
W
●
●
PGAV
VRGM
20
●
10
V
TVJ
TVJM
Tstg
-40...+140
140
-40...+125
°C
°C
°C
●
●
Contactless switches
VISOL
50/60 Hz, RMS
t = 1 min
t = 1 s
3000
3600
V~
V~
Advantages
●
Space and weight savings
Simple mounting
Improved temperature and power
IISOL £ 1 mA
●
Md
Mounting torque (M5)
Terminal connection torque (M8)
2.5-5/22-44 Nm/lb.in.
12-15/106-132 Nm/lb.in.
●
cycling
Reduced protection circuits
●
Weight
Typical including screws
320
g
Data according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1 - 4