MCC 250
MCD 250
ITRMS = 2x450 A
ITAVM = 2x287 A
VRRM = 800-1800 V
Thyristor Modules
Thyristor/Diode Modules
3
VRSM
VDSM
VRRM
VDRM
Type
7
2
6
5
4
1
V
V
Version 1
Version 1
900
1300
1500
1700
1900
800
1200
1400
1600
1800
MCC 250-08io1
MCC 250-12io1
MCC 250-14io1
MCC 250-16io1
MCC 250-18io1
MCD 250-08io1
MCD 250-12io1
MCD 250-14io1
MCD 250-16io1
MCD 250-18io1
3
3
6 7 1
5 4 2
Symbol
Conditions
Maximum Ratings
ITRMS, IFRMS
TVJ = TVJM
TC = 85°C; 180° sine
450
287
A
A
I
TAVM, IFAVM
MCC
MCD
ITSM, IFSM
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
9000
9600
A
A
1
5 4 2
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
7800
8500
A
A
∫i2dt
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
405 000
380 000
A2s
A2s
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
304 000
300 000
A2s
A2s
Features
• International standard package
• Direct copper bonded Al2O3 -ceramic
base plate
• Planar passivated chips
• Isolation voltage 3600 V~
• UL registered, E 72873
• Keyed gate/cathode twin pins
(di/dt)cr
TVJ = TVJM
;
repetitive, IT = 860 A
100
A/µs
f = 50 Hz; tP = 200 µs
VD = 2/3 VDRM
IG = 1 A;
diG/dt = 1 A/µs
non repetitive, IT = 290 A
VDR = 2/3 VDRM
800
A/µs
V/µs
(dv/dt)cr
PGM
TVJ = TVJM
;
1000
RGK = ∞; method 1 (linear voltage rise)
TVJ = TVJM
IT = ITAVM
;
tP = 30 µs
tP = 500 µs
120
60
W
W
Applications
;
• Motor control
• Power converter
• Heat and temperature control for
industrial furnaces and chemical
processes
PGAV
VRGM
20
10
W
V
TVJ
TVJM
Tstg
-40...+140
140
-40...+125
°C
°C
°C
• Lighting control
• Contactless switches
VISOL
50/60 Hz, RMS;
IISOL ≤ 1 mA;
t = 1 min
t = 1 s
3000
3600
V~
V~
Advantages
• Space and weight savings
• Simple mounting
Md
Mounting torque (M5)
Terminal connection torque (M8)
2.5-5/22-44 Nm/lb.in.
12-15/106-132 Nm/lb.in.
• Improvedtemperatureandpowercycling
• Reduced protection circuits
Weight
Typical including screws
320
g
Data according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
IXYS reserves the right to change limits, test conditions and dimensions
© 2004 IXYS All rights reserved
1 - 4