5秒后页面跳转
MBAA40W-A PDF预览

MBAA40W-A

更新时间: 2024-11-19 21:10:35
品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
1页 47K
描述
Power Supply Module

MBAA40W-A 技术参数

是否Rohs认证: 不符合生命周期:Obsolete
包装说明:,Reach Compliance Code:unknown
风险等级:5.92Base Number Matches:1

MBAA40W-A 数据手册

  
Condor  
World Class Medical Linear and Switching Power Supplies  
World Class Medical Linears, Single- and Multi-Output  
Features  
Features (Continued)  
c
c
c
c
c
c
Meets EMI Per FCC/VDE B  
c
c
c
c
c
c
36 Models (Single, Dual and Triple Output)  
Hermetically Sealed Power Transistors and ICs  
MTBF 200,000+ Hours Per Mil Handbook 217D  
8 Hour Burn-In with AC Cycling  
Try Before You Buy Ñ Free Evaluation Samples Available  
2 Year Warranty  
Three Power Levels (5-92 Watts)  
Approved to UL 544, IEC 601 and UL 2601  
AC Input: 110/120/220/240 VAC, 47-63 Hz  
Leakage Current: <10 µA  
OVP on All 5 V Outputs  
Specifications  
EACH  
Stock  
No.  
Mfr.Õs  
Type  
Leakage  
Current  
Size  
(Inches)  
AC Input: 100/120/220/240 VAC +10%, Ð13%, 47-63 Hz. Tolerance for  
230 VAC operation is +15%, Ð10%. Derate output current 10% for  
50 Hz operation. The L and LL case units have AC input of  
95-132/190-264 VAC, 47-63 Hz. This range can be extended to  
90-132/180-264 VAC by derating output current 20%.  
Output  
1-4  
5-24  
744-3085  
744-3090  
744-3095  
744-3100  
744-3105  
744-3110  
744-3115  
744-3120  
744-3125  
744-3130  
744-3230  
744-3235  
744-3245  
744-3250  
744-3255  
744-3260  
744-3265  
744-3270  
ML5-1/OVP-A  
MB5-3/OVP-A  
MC5-6/OVP-A  
MD5-12/0VP-A  
ML12-0.5-A  
MB12-1.7-A  
MC12-3.4-A  
MD12-6.8-A  
ML15-0.4-A  
MB15-1.5A  
MC15-3-A  
5 V @ 1.00 A  
5 V @ 3.00 A  
5 V @ 6.00 A  
5 V @ 12.0 A  
12 V @ 0.50 A  
12 V @ 1.70 A  
12 V @ 3.40 A  
12 V @ 6.80 A  
15 V @ 0.40 A  
15 V @ 1.50 A  
15 V @ 3.00 A  
15 V @ 6.00 A  
24 V @ 1.20 A  
24 V @ 2.40 A  
24 V @ 4.80 A  
28 V @ 1.00 A  
28 V @ 2.00 A  
28 V @ 4.00 A  
2.0 µA  
6.0 µA  
6.0 µA  
7.5 µA  
2.0 µA  
6.0 µA  
6.0 µA  
7.5 µA  
2.0 µA  
6.0 µA  
6.0 µA  
7.5 µA  
6.0 µA  
6.0 µA  
7.5 µA  
6.0 µA  
6.0 µA  
7.5 µA  
4.25 ´ 3.25 ´ 1.80  
4.88 ´ 4.00 ´ 2.25  
5.63 ´ 4.86 ´ 2.95  
9.00 ´ 4.86 ´ 3.30  
4.25 ´ 3.25 ´ 1.80  
4.88 ´ 4.00 ´ 2.25  
5.63 ´ 4.86 ´ 2.95  
9.00 ´ 4.86 ´ 3.30  
4.25 ´ 3.25 ´ 1.80  
4.86 ´ 4.00 ´ 2.25  
5.63 ´ 4.86 ´ 2.95  
9.00 ´ 4.86 ´ 3.30  
4.86 ´ 4.00 ´ 4.25  
5.63 ´ 4.86 ´ 2.95  
9.00 ´ 4.86 ´ 3.30  
4.86 ´ 4.00 ´ 2.25  
5.63 ´ 4.86 ´ 2.95  
9.00 ´ 4.86 ´ 3.30  
42.60  
51.33  
65.52  
101.57  
42.60  
50.34  
64.26  
105.01  
41.78  
51.33  
64.26  
99.61  
54.61  
66.57  
101.57  
51.33  
64.26  
99.61  
41.32  
49.79  
63.56  
92.97  
41.32  
48.28  
61.61  
100.81  
40.06  
49.79  
61.61  
95.52  
52.50  
63.56  
98.51  
49.79  
61.61  
95.52  
Line Regulation: ±0.05% for a 10% change.  
Load Regulation: ±0.05% for a 50% load change.  
Output Ripple: 3 mV +0.05% of output voltage, peak to peak maximum.  
Transient Response: ²50 microseconds for 50% load change.  
Short Circuit Protection: Automatic current limit/foldback.  
MD15-6-A  
MB24-1.2-A  
MC24-2.4-A  
MD24-4.8-A  
MB28-1-A  
MC28-2-A  
MD28-4-A  
Overload Protection: Built-in on all 5 V models, set at 6.2 V ± 0.4 V. Other  
models use optional overvoltage protection. OVP is not optional on L  
and LL case units; however, it is built-in on 5 V output models.  
Remote Sensing: Provided on all models, 3 amps and above, open sense lead  
protection built-in.  
Stability: ±0.05% for 24 hours after warmup.  
Multiple-Output  
Temperature Rating: 0 to 50¡C full rated, derated linearly to 40% at 70¡C.  
Temperature Coefficient: ±0.01%/¡C maximum.  
EACH  
Stock  
No.  
Mfr.Õs  
Type  
Output  
1
Output  
2
Output  
3
Leakage  
Current  
Size  
(Inches)  
1-4  
5-24  
Efficiency: 5 V units Ñ 45%; 12 and 15 V units Ñ 55%; 20 and 24 V units Ñ 60%.  
Vibration: Per Mil-Std-810D, Method 5143, Category 1, Procedure I.  
Shock: Per Mil-Std-810D, Method 5163, Procedure III.  
744-3135 MLL12-0.25-A +12  
V
V
@
@
0.25  
0.20  
1.0/0.8  
1.7/1.5  
3.4/3.0  
2.0  
3.0  
6.0  
6.0  
A
A
Ð12  
Ð15  
Ð12/15  
Ð12/15  
Ð12/15  
9-15  
9-15  
9-15  
18-24  
2.0 µA  
´ 3.25V´ 1.80 53.7@8  
´ 3.25V´ 1.80 53.0@5  
52.17  
49.26  
0.25  
0.20  
1.0/0.8  
1.7/1.5  
3.4/3.0  
0.5  
1.25  
2.5  
A
A
Ñ2.0  
Ñ2.0  
Ñ6.0  
Ñ6.0  
Ñ7.5  
Ñ6.0  
Ñ6.0  
Ñ7.5  
Ñ7.5  
µA  
µA  
µA  
µA  
µA  
µA  
µA  
µA  
µA  
4.25  
4.25  
6.50  
7.00  
9.38  
6.50  
7.00  
9.38  
9.38  
744-3140 MLL15-0.2-A  
744-3145 MAA15-0.8-A  
744-3150 MBB15-1.5-A  
744-3155 MCC15-3-A  
744-3160 MAA512-A  
744-3165 MBB512-A  
744-3170 MCC512-A  
744-3185 MCC524-A  
744-3200 MTLL-5W-A  
744-3205 MTAA-16W-A  
+15  
+12/15  
+12/15  
+12/15  
5
5
5
5
V
V
V
@
@
@
A
A
A
´ 4.00 ´ V2.25 58.93 @ 56.15  
´ 4.88 ´ V2.95 75.99 @ 72.03  
´ 4.88 ´ V3.30 109.24 @104.75  
´ 4.00V´ 2.25 65.34@ 62.65  
´ 4.88V´ 2.95 80.81@ 78.38  
´ 4.88V´ 3.30 117.81@ 112.97  
´ 4.88 ´V3.30 120.13 @ 116.51  
A
A
A
V
V
V
V
@
@
@
@
A
A
A
A
A
A
A
A
Remote Programming: Capability included on remote sense models.  
Safety Specifications: All models are approved to the following safety  
specifications Ñ IEC 601, VDE 0750, UL 544, CSA 22.2 #234, L3, UL  
2601-1 pending.  
2.0  
5 V @ 0.5 A  
5 V @ 2.0 A  
+12-15 V @ 0.1 A  
+12-15 V @ 0.4 A  
+12/15 V @ 1.0/0.8 A Ð12/15 V @ 1.0/0.8 A  
+12/15 V @ 1.0/0.8 A Ð12/15 V @ 1.0/0.8 A  
+12/15 V @ 1.7/1.5 A Ð12/15 V @ 1.7/1.5 A  
Ð12-15 V @ 0.1 A  
Ð12-15 V @ 0.4 A  
4.25 ´ 3.25 ´ 1.80 56.77  
6.50 ´ 4.00 ´ 2.25 82.95  
54.44  
70.35  
93.21  
6.0 µA  
744-3210 MBAA-40W-A 5 V @ 3.0 A  
744-3215 MCAA-60W-A 5 V @ 6.0 A  
744-3220 MCBB-75W-A 5 V @ 6.0 A  
6.0 µA 10.25 ´ 4.00 ´ 2.95 96.10  
7.5 µA  
7.5 µA 11.00 ´ 4.88 ´ 3.30 128.86 124.99  
EMI Specifications: All models are tested to meet or exceed the conducted  
emissions requirements of FCC 20870, Class B and VDE 0871, Class  
B without the addition of external filters.  
9.00 ´ 4.88 ´ 3.30 116.86 113.34  
125 Watt Global Performance Switchers Ñ GPFC125 Commercial/GPFM125 Medical  
Features  
Ñ NEW Ñ  
c
c
c
c
Compact 125 Watt Multiple Output  
c
c
c
c
Small Package 6.00" ´ 3.5" ´ 1.5"  
AC Input 90-264 Vac, 47-63 Hz Single Phase  
Power Density of 4 Watts Per Cubic Inch  
Power Factor Correction to Meet EN61000-3-2  
Commercial Approved to UL1950, IEC950, CSA22.2 No. 950 and EN60950  
Medical Approved to UL2601, IEC601-1, CSA22.2 No. 601-1, EN60601  
CE Marked to LVD  
12  
Voltage  
Commercial Model  
EACH  
Medical Model  
Output  
Max.  
(A)*  
Voltage  
Max.  
(A)  
Voltage  
Adjustment  
OVP  
Set.  
Total  
Reg.  
Ripple  
and Noise  
EACH  
Output  
No.  
Output  
(V)  
Stock  
No.  
Mfr.Õs  
No.  
Stock  
No.  
Mfr.Õs  
No.  
1-4  
5-24  
1-4  
5-24  
1
2
3à  
4
+5.0  
+12.0  
12.0  
9.0  
4.0  
2.5  
0.2  
16.0  
7.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
744-4200  
744-4205  
744-4210  
744-4215  
744-4220  
744-4225  
744-4230  
744-4235  
GPFC125A  
GPFC125B  
GPFC125C  
GPFC125D  
GPFC125E  
GPFC125F  
GPFC125G  
GPFC125H  
175.95  
171.06  
744-4240  
744-4245  
744-4250  
744-4255  
744-4260  
744-4265  
744-4270  
744-4275  
GPFM125A  
GPFM125B  
GPFM125C  
GPFM125D  
GPFM125E  
GPFM125F  
GPFM125G  
GPFM125H  
206.55  
206.55  
206.55  
206.55  
206.55  
206.55  
206.55  
206.55  
200.81  
Ð12.0  
1.0  
1%  
1
2
3à  
4
+5.0  
+12.0  
12.0  
9.0  
4.0  
2.5  
0.2  
16.0  
7.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
175.95  
175.95  
175.95  
175.95  
175.95  
175.95  
175.95  
171.06  
171.06  
171.06  
171.06  
171.06  
171.06  
171.06  
200.81  
200.81  
200.81  
200.81  
200.81  
200.81  
200.81  
Ð5.0  
1.0  
1%  
1
2
3à  
4
5.0  
12.0  
15.0  
9.0  
4.0  
2.5  
0.2  
16.0  
7.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
Ð15.0  
1.0  
1%  
1
2
3à  
4
+5.0  
+24.0  
12.0  
9.0  
3.0  
2.5  
0.2  
16.0  
4.5  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
Ð12.0  
1.0  
1%  
1
2
3à  
4
+5.0  
+24.0  
15.0  
9.0  
3.0  
2.5  
0.2  
16.0  
4.5  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
Ð15.0  
1.0  
1%  
1
2
3à  
4
+5.0  
+15.0  
15.0  
9.0  
3.5  
2.5  
0.2  
16.0  
6.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
Ñ1%  
1%  
1%  
1%  
Ð5.0  
1.0  
1%  
1
2
3à  
4
+5.0  
+3.3  
12.0  
9.0  
7.0  
2.5  
0.2  
16.0  
10.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
6.2 ±0.6 V  
4.2 ±0.6 V  
1%  
1%  
1%  
1%  
2%  
Ð12.0  
1.0  
1%  
1
2
3à  
4
+3.3  
+5.0  
12.0  
9.0  
4.0  
2.5  
0.2  
16.0  
7.0  
4.0  
±5%  
±5%  
Ñ1Ñ%  
Ñ1Ñ%  
4.2 ±0.6 V  
6.2 ±0.6 V  
1%  
1%  
1%  
2%  
1%  
Ð12.0  
1.0  
1%  
*Continuous ratings for unrestricted convection cooling. Peak rating or continuous rating with 150 LFM air cooing. àOutput 3 is isolated. Can be connected as + or Ð output.  
684  
b
ALLIED  
See Our Manufacturer Index Located In Section 1  

与MBAA40W-A相关器件

型号 品牌 获取价格 描述 数据表
MBA-EE7756/11+ MINI

获取价格

Double Balanced Mixer, 1300MHz Min, 3993MHz Max, CASE SM2, 10 PIN
MBA-EE7756/15 MINI

获取价格

Double Balanced Mixer, 1950MHz Min, 4000MHz Max, CASE SM2, 10 PIN
MBA-EE7756/15+ MINI

获取价格

Double Balanced Mixer, 1950MHz Min, 4000MHz Max, CASE SM2, 10 PIN
MBA-EE7756/17 MINI

获取价格

Double Balanced Mixer, 1400MHz Min, 4150MHz Max, CASE SM2, 10 PIN
MBA-EE7756/2 MINI

获取价格

Double Balanced Mixer, 1200MHz Min, 4500MHz Max, CASE SM2, 10 PIN
MBA-EE7756/23+ MINI

获取价格

Double Balanced Mixer, 2200MHz Min, 4160MHz Max, CASE SM2, 10 PIN
MBA-EE7756/24 MINI

获取价格

Double Balanced Mixer, 1800MHz Min, 4100MHz Max, CASE SM2, 10 PIN
MBA-EE7756/28 MINI

获取价格

Double Balanced Mixer, 780MHz Min, 1990MHz Max, CASE SM2, 10 PIN
MBA-EE7756/28+ MINI

获取价格

Double Balanced Mixer, 780MHz Min, 1990MHz Max, CASE SM2, 10 PIN
MBA-EE7756/29+ MINI

获取价格

Double Balanced Mixer, 1800MHz Min, 5050MHz Max, CASE SM2, 10 PIN