MAAP-011022
7 W Pulsed High Power Amplifier
2.7 - 3.0 GHz, 6 mm PQFN 28-LD
Rev. V3
Features
Functional Block Diagram
7 W Pulsed Output Power (Saturated)
23 dB Gain
+10 V Bias Operation
50 Ω Impedance, Balanced Design
Lead-Free 6 mm 28-lead PQFN Package
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
VGAx
VDAx
-5 V
TSENSE
RFIN
RFOUT
90°
90°
Description
The MAAP-011022 is a 2.7 to 3.0 GHz high power
balanced amplifier, which is designed for S-Band
aviation and weather radar applications. This device
puts out 7 W pulsed and is designed to operate at an
8% duty cycle.
DETOUT
HPACNTRL
VDBx
VGBx
The MAAP-011022 is packaged in a lead-free 6 mm
28-lead plastic package for high volume
manufacturing. This IC utilizes one of MACOM’s
advanced 0.5 µm processes, which has been
optimized so amplifiers, passives, and control
components can be combined on a single IC.
Pin Configuration3,4,5,6
Pin No.
Function
VD2A
Pin No.
Function
VCOUT
1
2
15
16
17
18
19
20
21
22
23
24
25
26
27
28
297
No Connection
VD1A
VG1B
3
VG2B
This MAAP-011022 is specifically targeted for
avionics and weather radar.
4
No Connection
VG2A
No Connection
VD1B
5
6
VG1A
No Connection
VD2B
7
No Connection
No Connection
RFIN
8
No Connection
RFOUT
9
Ordering Information1,2
10
11
12
13
14
No Connection
No Connection
No Connection
HPACNTRL
No Connection
No Connection
No Connection
DETOUT
Part Number
Package
MAAP-011022-TR0500
MAAP-011022-001SMB
500 piece reel
Sample Test Board
-5 V
TSENSE
1. Reference Application Note M513 for reel size information.
2. Sample board includes 5 loose parts.
Ground Pad
3. See the evaluation board schematic for the recommended
external components.
4. VDAx and VDBx are connected to the +10 V bias.
5. The gates are controlled internally from the bias circuit shown
on the evaluation board schematic but need to be bypassed
as shown. VGAx must be connected to VGBx.
6. HPACNTRL is tied to +5 V for drain switching. For gate
switching the PA is turned off when HPACNTRL is at 0 V.
7. The exposed pad centered on the package bottom must be
connected to RF, DC and thermal ground.
*Restrictions on Hazardous Substances,
European Union Directive 2011/65/EU.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support