RoHS
Compliant
RF Driver Amplifier
250 - 4000 MHz
MAAMSS0056
V1
Features
Functional Block Diagram
•
•
•
•
•
•
•
•
Broadband Operation
Output Intercept Point Greater than +40 dBm
Excellent ACPR performance
High Efficiency
Lead-Free SOIC-8EP Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
M/A-COM’s MAAMSS0056 RF driver amplifier is a
two stage GaAs MMIC which exhibits exceptional
linearity performance as well as featuring high gain
in a lead-free SOIC-8EP surface mount plastic
package. The device runs off a single +5 volt supply
and draws 190 mA typically.
Pin Configuration 4
Pin No.
Pin Name
VCC1
Description
1st Stage VCC & RF Output
No Connection
The MAAMSS0056 is fabricated using a high
reliability GaAs HBT process to realize low current
and high power functionality. The process features
full passivation for increased performance and
reliability.
1
2
3
4
N/C
N/C
No Connection
RFIN
N/C
Amplifier Input
5
No Connection
The MAAMSS0056 has been designed to be a
functional driver amplifier from 250 to 4000 MHz.
6
7
8
RFOUT/ VCC2
N/C
Amplifier Output & 2nd Stage VCC
No Connection
RFIN2
2nd Stage RF Input
Ordering Information 1
4. The exposed pad centered on the package bottom must be
connected to the RF and DC ground.
Part Number
MAAMSS0056
Package
Bulk Packaging
3000 piece reel
MAAMSS0056TR-3000
Maximum Operating Conditions 5
MAAMSS0056SMB
2140 MHz Configuration
Parameter
Maximum Operating
Conditions
MAAM-000056-000SMB
Sample Only, General Frequency
Junction Temperature 6
160°C
1. Reference Application Note M513 for reel size information.
RF Output Power
28.5 dBm
Absolute Maximum Ratings 2,3
Operating Temperature
-40°C to +85°C
Parameter
Absolute Maximum
5. Operating at or within these conditions will ensure MTTF > 1 x
106 hours.
6. Typical thermal resistance (Өjc) = 65°C/W.
RF Output Power
Voltage
29 dBm
6 volts
Storage Temperature
-65°C to +150°C
Junction Temperature
200°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.