MODEL: M2XV2
Super-mini Signal Conditioners Mini-M Series
[2] OUTPUT
Current
Z1: Range 0 – 20 mA DC
Voltage
SIGNAL TRANSMITTER
(PC programmable)
V1: Range -2.5 – +2.5 V DC
V2: Range -10 – +10 V DC
Functions & Features
• Converts DC input from a sensor into a standard process
signal
(Configurator software is used to change output over the
described range of the selected suffix code. For changing
out of this range, set the Output Range Selectors inside the
unit before software adjustment.)
• PC programmable
Typical Applications
• Isolation between control room and field instrumentation
• Ideal for quick spare part
[3] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
23 (.91)
47 – 66 Hz)
(90 – 264 V for UL)
DC Power
M
od
el
76
(2.99)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
124
(4.88)
mm (inch)
[4] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
MODEL: M2XV2–[1][2]–[3][4]
/CE: CE marking
/UL: UL approval, CE marking
Other Options
ORDERING INFORMATION
• Code number: M2XV2-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. M2XV2-S2Z1-R/CE/Q)
blank: none
/Q: Option other than the above (specify the specification)
• Input range (e.g. 1 – 5 V DC)
• Output range (e.g. 4 – 20 mA DC)
Specify the specification for option code /Q
(e.g. /C01/S01)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
[1] INPUT
Current
/S01: Stainless steel (UL not available)
Z1: Range 0 – 50 mA DC (Input resistance 100 Ω)
Voltage
S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.)
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)
(Configurator software is used to change input over the
described range of the selected suffix code. For changing
out of this range (between S1 and S2), set the Input Range
Selector on the side of unit before software adjustment.
For a current input, set the Selector to the same setting as
for S2 and use a receiving resistor.)
RELATED PRODUCTS
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
M2XV2 SPECIFICATIONS
ES-5081 Rev.9 Page 1/4
http://www.m-system.co.jp/