MODEL: M2XUM
Current
Super-mini Signal Conditioners Mini-M Series
Z1: Range 0 – 50 mA DC (Input resistance 100 Ω)
Voltage
UNIVERSAL TRANSMITTER
(PC programmable; Modbus-RTU communication)
Functions & Features
S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.)
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)
Thermocouple
• Accepts direct inputs from various sensors and provides a
standard process signal
T1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F)
T2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F)
T3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F)
T4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F)
T5: T (CC) (Usable range -270 to +400°C, -454 to +752°F)
T6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F)
T7: R (Usable range -50 to +1760°C, -58 to +3200°F)
T8: S (Usable range -50 to +1760°C, -58 to +3200°F)
T9: C (WRe 5-26) (Usable range 0 to 2315°C, 32 to 4199°F)
TN: N (Usable range -270 to +1300°C, -454 to +2372°F)
TU: U (Usable range -200 to +400°C, -328 to +752°F)
TL: L (Usable range -200 to +900°C, -328 to +1652°F)
TP: P (Platinel II) (Usable range 0 to 1395°C, 32 to 2543°F)
T0: Specify (Please provide an emf table.)
RTD
• I/O types and calibration ranges are fully programmable
via a PC
• Linearization up to 100 points can be programmed for DC
and potentiometer inputs
• Isolation between input – output – RS-485 – power
Typical Applications
• Signal conversion between control room and field
instrumentation with isolation
• Ideal for use as a fast solution, multifunctional spare part
29.5 (1.16)
(2- or 3-wire)
Model
76
(2.99)
R1: JPt 100 (JIS'89)
(Usable range: -200 to +500°C, -328 to +932°F)
R3: Pt 100 (JIS'89)
(Usable range: -200 to +850°C, -328 to +1562°F)
R4: Pt 100 (JIS'97, IEC)
124
(4.88)
mm (inch)
(Usable range: -200 to +850°C, -328 to +1562°F)
R5: Pt 50 Ω (JIS'81)
(Usable range: -200 to +649 °C, -328 to +1200°F)
R6: Ni 508.4 Ω
MODEL: M2XUM–[1][2]–[3][4]
(Usable range: -50 to +200°C, -58 to +392°F)
R7: Pt 1000
ORDERING INFORMATION
• Code number: M2XUM-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. M2XUM-00-M2/CE/Q)
(Usable range: -200 to +200°C, -328 to +392°F)
R8: Ni 100 (Usable range: -50 to +200°C, -58 to +392°F)
R9: Cu 10 @25°C
• Specify the specification for option code /Q
(e.g. /C01/S01)
(Usable range: -50 to +200°C, -58 to +392°F)
R0: Specify (Please provide a resistance table.)
Potentiometer
Non-specified orders will be shipped at default factory
settings (M2XUM-00: 4 – 20 mA input/4 – 20 mA output).
However, the power suffix code must be specified.
If you specify full code numbers without specific calibration
ranges, default settings will be used.
M: Total resistance 100 Ω – 10 kΩ
Note: Consult M-System for 2-wire RTD
[2] OUTPUT
0: User-calibrated (Factory default: 4 – 20 mA DC)
Note: Must be used with its socket. NOT installable to a
multi-unit installation base. (e.g. model: M2BS-16)
If the unit is to be factory-calibrated to a specific
output type, please select from the following:
Current
[1] INPUT
0: User-calibrated (Factory default: 4 – 20 mA DC)
Z1: Range 0 – 20 mA DC
Voltage
If the unit is to be factory-calibrated to a specific
input type, please select from the following:
V1: Range -2.5 – +2.5 V DC
V2: Range -10 – +10 V DC
M2XUM SPECIFICATIONS
ES-5009 Rev.19 Page 1/7