MODEL: M2XT2
5: T (CC)
6: B (RH)
7: R
Super-mini Signal Conditioners Mini-M Series
THERMOCOUPLE TRANSMITTER
(PC programmable)
8: S
9: C (WRe 5-26)
N: N
Functions & Features
• Accepts direct input from a thermocouple and provides a
linearized process signal
U: U
L: L
• PC programmable
P: P (Platinel II)
0: Specify
• Wide selection of thermocouples
• User’s temperature table can be used
• Leadwire resistance compensation
(Configurator software is used to change the input type and
precise range.)
Typical Applications
[2] OUTPUT
Current
• Small burnout sensing current enables long distance
transmission with minimum offset drifts
• Electric furnace (isolation ensured even when 200 V AC
power for heater leaks through furnace wall)
• No burnout type can connect to a single T/C in parallel
with a recorder
Z1: Range 0 – 20 mA DC
Voltage
V1: Range -2.5 – +2.5 V DC
V2: Range -10 – +10 V DC
(Configurator software is used to change output over the
described range of the selected suffix code. For changing
out of this range, set the Output Range Selectors inside the
unit before software adjustment.)
• Ideal for quick spare part
23 (.91)
[3] POWER INPUT
AC Power
Model
76
(2.99)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(90 – 264 V for UL)
124
(4.88)
DC Power
mm (inch)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
MODEL: M2XT2–[1][2]-[3][4]
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
ORDERING INFORMATION
• Code number: M2XT2-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. M2XT2-2Z1-M2/BL/CE/Q)
[4] OPTIONS (multiple selections)
Burnout
blank: Upscale burnout
K thermocouple setting will be used if the input code is not
specified.
/BL: Downscale burnout
(UL not available)
• Temperature range (e.g. 0 – 800°C)
• Output range (e.g. 4 – 20 mA DC)
• Specify the specification for option code /Q
(e.g. /C01/S01)
/BN: No burnout
(UL not available)
Standards & Approvals (must be specified)
/N: Without CE or UL
/CE: CE marking
[1] INPUT THERMOCOUPLE
1: (PR)
/UL: UL approval, CE marking
Other Options
2: K (CA)
3: E (CRC)
4: J (IC)
blank: none
/Q: Option other than the above (specify the specification)
M2XT2 SPECIFICATIONS
ES-5062 Rev.16 Page 1/5
http://www.m-system.co.jp/