MODEL: M2XRP2
Super-mini Signal Conditioners Mini-M Series
[1] INPUT
0: User-calibrated (Factory default: open collector, 0 – 100 kHz)
ENCODER SPEED TRANSMITTER
(PC programmable; built-in excitation)
Functions & Features
If the unit is to be factory-calibrated to a specific
input type, please select from the following:
A: Open collector
• Converts a two-phase forward and reverse rotation
pulse signal with 90 degree phase difference into a forward
and reverse speed signal
B: Voltage pulse
J: RS-422 line driver pulse
• Built-in excitation
• PC programmable input and output ranges
• Input pulse monitoring LED
[2] EXCITATION
0: User-calibrated (Factory default: 12 V DC / 5 mA)
• Direct RS-422 input
If the unit is to be factory-calibrated to a specific
voltage value, please select from the following:
1: 5 V DC / 5 mA
Typical Applications
• Measuring moving speed of a machine with a rotary
encoder
4: 12 V DC / 5 mA
[3] OUTPUT
29.5 (1.16)
0: User-calibrated (Factory default: 4 – 20 mA)
M
od
el
If the unit is to be factory-calibrated to a specific
output type, please select from the following:
Current
76
(2.99)
Z1: Range 0 – 20 mA DC
124
(4.88)
Voltage
V1: Range -2.5 – +2.5 V DC
mm (inch)
V2: Range -10 – +10 V DC
(Configurator software is used to change output over the
described range of the selected suffix code. For changing
out of this range, set the Output Range Selectors inside the
unit before software adjustment.)
MODEL: M2XRP2-[1][2][3]-[4][5]
ORDERING INFORMATION
• Code number: M2XRP2-[1][2][3]-[4][5]
[4] POWER INPUT
AC Power
Specify a code from below for each [1] through [5].
(e.g. M2XRP2-000-M2/CE/Q)
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
• Specify the specification for option code /Q
(e.g. /C01/S01)
47 – 66 Hz)
(90 – 264 V for UL)
• Non-specified orders will be shipped at default factory
settings (M2XRP2-000: Open collector input/12 V
excitation/4 – 20 mA output). However, a power suffix code
must be specified.
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
If you specify a full code number without specific calibration
ranges, the input frequency is factory set to the maximum
range available for the selected input code and the output is
set to the default range. Use Ordering Information Sheet
(No. ESU-5059).
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
Note: Must be used with its socket. NOT installable to a
multi-unit installation base. (e.g. model: M2BS-16)
http://www.m-system.co.jp/
M2XRP2 SPECIFICATIONS
ES-5059 Rev.12 Page 1/6