Series 682
1A, 250 Vrms Optically Isolated
AC Solid-State Relay
Part*
Mil Spec
Number
Relay Description
Number
682-1Y
M28750/9-001 1A, 250 Vrms, AC Solid-State Relay
(2A with Heatsink)
* The Y suffix denotes parameters tested to MIL-PRF-28750 test methods.
The W suffix denotes parameters tested to Teledyne specifications.
FEATURES
ELECTRICAL SPECIFICATIONS
(-55°C TO +110°C UNLESS OTHERWISE SPECIFIED)
INPUT (CONTROL) SPECIFICATIONS
• Relay Qualified to MIL-PRF-28750
• Zero voltage turn-on SCR output
• Optical isolation
Min
Max
Units
• Logic compatible input
Input Current (See Figure 1)
VIN = 5 Vdc
• Low minimum output current
• Extremely low EMI
15
16
mAdc
mAdc
VIN=32 Vdc
• Low profile metal DIP package
Turn-Off Voltage (Guaranteed Off)
1.5
Vdc
DESCRIPTION
Turn-On Voltage (Guaranteed On)
Reverse Voltage Protection
3.8
3.8
Vdc
Vdc
This state-of-the-art solid-state relay
is designed for use in AC power
switching applications. The output is
rated for 1A at 250 Vrms and can
operate from 40 to 440 Hz for
resistive and reactive loads with
power factors as low as 0.2. Back-
to-back SCRs are configured for
zero voltage turn-on and can handle
current surges up to 8A. The
patented circuit design assures the
lowest possible EMI by virtually
eliminating commutation spikes
while maintaining excellent noise
immunity. Optical isolation allows
safe control of AC loads from low
level logic circuits. The low-profile
metal DIP package is hermetically
-32
32
Input Voltage Range
Vdc
OUTPUT (LOAD) SPECIFICATIONS
Min
0.2
20
Max
Units
Arms
Vrms
Output Current Rating (See Figure 3)
Output Voltage Rating
2.0
250
Frequency Range
40
440
Hz
Output Voltage Drop
@ -55 ºC
1.8
Vrms
@ 1 Amp
@ 25 ºC
@ 110 ºC
1.6
1.5
Vrms
Vrms
(See Figure 4)
sealed
to
withstand
severe
Off-State Leakage Current (250 Vac, 400 Hz)
1.0
mArms
environmental
conditions
encountered in military and
aerospace applications. This relay is
qualified to MIL-PRF-28750/9-001
and is available to Y screening
levels.
Turn-On Time
1/2
1
Cycle
Cycle
Turn-Off Time
Transient Voltage (T < 5 s)
+500
8
Vpk
Apk
Surge Current @ 25o C (16 ms)
(See Figure 2)
Overload (Repetitive, 10% Duty Cycle)
Zero Voltage Turn-On Point at 25o C
1.5
Arms
Vpk
WIRING DIAGRAM
+15
TYPICAL INTERFACE TO 5 VOLT LOGIC
(WITH SUGGESTED dv/dt SUPPRESSION - SEE NOTE 2)
Off-State dv/dt
200
V/μs
(with Snubber - See Note 2)
Load Power Factor (See note 3)
Insulation Resistance @ 500 Vdc
Isolation (Input to Output)
0.2
109
1
Ohm
pF
10
Dielectric Withstanding Voltage
1500
Vac
682 76
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
682\072002\Q1