LT6119-1/LT6119-2
Current Sense Amplifier,
Reference and Comparators
with POR
FeaTures
DescripTion
The LT®6119 is a complete high side current sense device
that incorporates a precision current sense amplifier, an
integratedvoltagereferenceandtwolatchingcomparators.
Two versions of the LT6119 are available. The LT6119-1
has the comparators connected in opposing polarity and
the LT6119-2 has the comparators connected in the same
polarity.Thecomparatorlatchfunctionalitycanbeenabled
ordisabledandthecomparatorscanbeconfiguredtoreset
upon power-on. The input and the open-drain outputs of
the comparators are independent from the current sense
amplifier. The comparator trip points and amplifier gain
are configured with external resistors.
n
Current Sense Amplifier
– Fast Step Response: 500ns
– Low Offset Voltage: 200µV Maximum
– Low Gain Error: 0.2% Maximum
n
Internal 400mV Precision Reference
n
Internal Latching Comparators
– Power-On Reset Capability
– Fast Response Time: 500ns
– Total Threshold Error: 1.25% Maximum
– Two Comparator Polarity Options
n
Wide Supply Range: 2.7V to 60V
n
Supply Current: 550µA
n
Specified for –40°C to 125°C Temperature Range
The overall propagation delay of the LT6119 is typically
only 1.4µs, allowing for quick reaction to overcurrent and
undercurrent conditions. The 1MHz bandwidth allows the
LT6119 to be used for error detection in critical applica-
tions such as motor control. The high threshold accuracy
of the comparators, combined with the ability to latch
both comparators, ensures the LT6119 can capture high
speed events.
n
Available in 10-Lead MSOP Package
applicaTions
n
Overcurrent, Undercurrent and Fault Detection
n
Current Shunt Measurement
n
Battery Monitoring
Motor Control
Automotive Monitoring and Control
Industrial Control
n
n
The LT6119 is fully specified for operation from –40°C
to 125°C, making it suitable for industrial and automo-
tive applications. The LT6119 is available in a small
10-lead MSOP.
n
L, LT, LTC, LTM, TimerBlox, Linear Technology and the Linear logo are registered trademarks of
Linear Technology Corporation. All other trademarks are the property of their respective owners.
Typical applicaTion
Response to Overcurrent Event
Fast Acting Fault Protection with Power-On Reset and Early Warning
0.1Ω
IRF9640
12V
TO LOAD
V
LOAD
10V/DIV
0V
0.1µF
6.2V*
100Ω
1k
3.3V
24.9k
SENSEHI SENSELO
+
V
OUT
V
OUTA
I
LOAD
10k 1.62k 100k
LT6119-2
6.04k
2.37k
200mA/DIV
0mA
LE
100nF
INC2
V
OUTC1
5V/DIV
1k
250mA DISCONNECT
100mA WARNING
OUTC2
OUTC1
0V
0V
100mA WARNING
V
OUTC2
5V/DIV
2N2700
INC1
250mA DISCONNECT
–
V
1.6k
611912 TA01b
5µs/DIV
611912 TA01a
*CMH25234B
611912f
1