100W Single Output Switching Power Supply
LPV-100 series
Features :
Constant voltage design
Universal AC input / Full range
Fully encapsulated with IP67 level (Note.8)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications(Note 7.)
2 years warranty
IP67
SPECIFICATION
MODEL
LPV-100-5
LPV-100-12
LPV-100-15
LPV-100-24
LPV-100-36
LPV-100-48
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
12A
8.5A
6.7A
4.2A
2.8A
2.1A
0 ~ 12A
60W
0 ~ 8.5A
102W
120mVp-p
5.0%
0 ~ 6.7A
100.5W
120mVp-p
0 ~ 4.2A
100.8W
150mVp-p
0 ~ 2.8A
100.8W
150mVp-p
0 ~ 2.1A
100.8W
150mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 8.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
1.0%
6.0%
2.0%
Note.6 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
50ms/230VAC
Note.4 90 ~ 264VAC
47 ~ 63Hz
14ms/115VAC at full load
127 ~ 370VDC
80%
85%
87%
88%
88%
89%
INPUT
2.2A/115VAC 1.2A/230VAC
COLD START 30A/115VAC
0.25mA / 240VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
75A/230VAC
110 ~ 150% rated output power
OVER CURRENT
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
PROTECTION
ENVIRONMENT
41.4 ~ 48.6V
55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
IP67 approved; Design refer to TUV EN60950-1, EN61347-2-13
I/P-O/P:3KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2 Class A( 80% load), EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A
703Khrs min. MIL-HDBK-217F (25
190*52*37mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.63Kg;20pcs/13.6Kg/0.57CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. In the European market this product is only suitable for LED lighting applications that don t have to comply with the harmonic current requirements of
EN61000-3-2 Class C.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
File Name:LPV-100-SPEC 2011-03-09