Embedded Power for
Business-Critical Continuity
Rev. 10.9.09_141
LPT100-M Series
1 of 3
LPT100-M Series
130 Watts
Total Power:
Input Voltage: 90ꢀ-ꢀ264ꢀVac
# of Outputs: Triple
80 - 130 Watts
Electrical Specifications
Special Features
•ꢀ MedicalꢀandꢀITEꢀsafeties
•ꢀ Activeꢀpowerꢀfactorꢀcorrection
•ꢀ 2”ꢀxꢀ4”ꢀfootprint
•ꢀ Lessꢀthanꢀ1Uꢀhigh
•ꢀ EN61000-3-2ꢀcompliant
•ꢀ Remoteꢀsense
Input
Inputꢀrange:
Frequency:
90ꢀ-ꢀ264ꢀVac;ꢀ127ꢀ-ꢀ300ꢀVdc
47ꢀ-ꢀ63ꢀHz
Inrushꢀcurrent:
Efficiency:
EMI/RFI:
50ꢀAꢀmax.,ꢀcoldꢀstartꢀ@ꢀ25ꢀ°C
82%ꢀtypicalꢀatꢀfullꢀload
FCCꢀClassꢀBꢀconducted;ꢀCISPR22ꢀClassꢀBꢀconducted;ꢀ
EN55022ꢀClassꢀBꢀconducted;ꢀVDE0878PT3ꢀClassꢀBꢀconducted
275ꢀµAꢀ@ꢀ50/60ꢀHz,ꢀ264ꢀVacꢀinput
•ꢀ Powerꢀfail
•ꢀ Adjustableꢀmainꢀoutput
•ꢀ Built-inꢀClassꢀBꢀEMIꢀfilter
•ꢀ Overvoltageꢀprotection
•ꢀ Overloadꢀprotectionꢀ
•ꢀ Thermalꢀoverloadꢀprotection
•ꢀ LPX50ꢀenclosureꢀkitꢀavailable
Safetyꢀgroundꢀ
leakageꢀcurrent:
Output
Maximumꢀpower:
80ꢀWꢀforꢀconvection;
130ꢀWꢀwithꢀ200ꢀLFMꢀforcedꢀair
Adjustmentꢀrange:
Hold-upꢀtime:
Allꢀoutputsꢀadjustableꢀ-ꢀ40%,ꢀ+10%,ꢀexceptꢀforꢀ+24VꢀoutputꢀonꢀLPT104-Mꢀ
whichꢀwillꢀbeꢀ-10%,ꢀ+20%ꢀandꢀ3.3ꢀVꢀoutputꢀonꢀtheꢀLPT101-Mꢀ+10%,ꢀ-15%
10ꢀmsꢀ@ꢀ130ꢀWꢀload,ꢀ120ꢀVacꢀinput
Overloadꢀprotection: Shortꢀcircuitꢀprotectionꢀonꢀallꢀoutputs.ꢀCaseꢀoverloadꢀ
protectedꢀ@ꢀ110ꢀ-ꢀ160%ꢀaboveꢀratingꢀforꢀV1ꢀ&ꢀV2,ꢀ110-190%ꢀforꢀV3
Overvoltageꢀprotection: 15ꢀ-ꢀ35%ꢀaboveꢀnominalꢀoutput
LogicalꢀControl
Powerꢀfailure:
ActiveꢀLowTTLꢀlogicꢀsignalꢀgoesꢀhighꢀ100ꢀ-ꢀ500ꢀmsecꢀafterꢀmainꢀoutput;ꢀitꢀ
goesꢀlowꢀatꢀleastꢀ6ꢀmsecꢀbeforeꢀlossꢀofꢀregulation
Remoteꢀsense:
Compensatesꢀforꢀ0.5ꢀVꢀleadꢀdropꢀmin.ꢀWillꢀoperateꢀwithoutꢀremoteꢀsenseꢀ
connected.ꢀReverseꢀconnectionꢀprotected.
Safety
•ꢀ ꢀꢀTUVꢀ ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ60950,ꢀ60601-1
•ꢀ ꢀꢀUL
60950,ꢀ60601-1
60950,ꢀ60601-1
60950,ꢀ60601-1
60950,ꢀ60601-1ꢀ
Certificateꢀ&ꢀreport
Markꢀ(LVD)
•ꢀ ꢀꢀCSA
•ꢀ ꢀꢀNEMKO
•ꢀ ꢀꢀAUSTEL
•ꢀ ꢀꢀCB
•ꢀ ꢀꢀCE