25W Single Output Switching Power Supply
LPF-25D series
Features :
Universal AC input / Full range (up to 305VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class power unit, no FG
Class 2 power unit
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
SELV
IP67
( for 48V,54V only)
( except for 48V,54V )
SPECIFICATION
MODEL
LPF-25D-12 LPF-25D-15 LPF-25D-20 LPF-25D-24 LPF-25D-30 LPF-25D-36 LPF-25D-42 LPF-25D-48 LPF-25D-54
36V
42V
DC VOLTAGE
12V
15V
20V
24V
30V
48V
54V
18 ~ 36V
0.7A
21 ~ 42V
0.6A
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
1.67A
10 ~ 20V
1.25A
25W
12 ~ 24V
1.05A
25.2W
150mVp-p
4.0%
15 ~ 30V
0.84A
25.2W
200mVp-p
4.0%
24 ~ 48V
0.53A
27 ~ 54V
0.47A
RATED CURRENT
RATED POWER
2.1A
25.2W
250mVp-p
4.0%
25.2W
250mVp-p
4.0%
25.2W
25.05W
150mVp-p
4.0%
25.44W
250mVp-p
4.0%
25.38W
350mVp-p
4.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3 4.0%
150mVp-p
4.0%
OUTPUT
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
Note.7 1500ms, 80ms / 115VAC at full load 1500ms, 80ms / 230VAC
16ms at full load 230VAC /115VAC
Note.5 90 ~ 305VAC
127 ~ 431VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
84%
85%
85.5%
85.5%
86%
86%
84%
85.5%
85.5%
0.4A / 115VAC
0.2A / 230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 50A/230VAC
<0.75mA / 240VAC
95 ~ 108%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION
SHORT CIRCUIT
OVER VOLTAGE
34 ~ 40V
41 ~ 49V
46 ~ 54V
54 ~ 63V
59 ~ 66V
15 ~ 18V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
95J Ó5J( TSW1) Detect on U2
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recover automatically after temperature goes down
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.6
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V),EN61347-1, EN61347-2-13 independent, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015; EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level(surge 2KV), criteria A
EMC IMMUNITY
MTBF
418.5Khrs min. MIL-HDBK-217F (25
148*40*32mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.36Kg; 40pcs/ 15.4Kg/1.02CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight explosure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:LPF-25D-SPEC 2011-12-21