45W Single Output LED Power Supply
PLN-45 series
Features :
Universal AC input / Full range
Fully isolated plastic case with IP64 level
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
110
SELV
EQUIVALENT
F
M
M
( for 48V only)
( except for 48V )
IP64
LPS
SPECIFICATION
MODEL
PLN-45-12
PLN-45-15
PLN-45-20
PLN-45-24
PLN-45-27
PLN-45-36
PLN-45-48
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT
OPERATION VOLTAGE Note.7
8.4 ~ 12V
10.5 ~15V
14 ~ 20V
16.8 ~24V
18.9 ~27V
25.2 ~ 36V
33.6 ~ 48V
RATED CURRENT
CURRENT RANGE
RATED POWER
3.8A
3A
2.3A
1.9A
1.7A
1.25A
0.95A
0 ~ 3.8A
45.6W
0 ~ 3A
45W
0 ~ 2.3A
46W
0 ~ 1.9A
45.6W
0 ~ 1.7A
45.9W
0 ~ 1.25A
45W
0 ~ 0.95A
45.6W
RIPPLE & NOISE (max.) Note.2 2Vp-p
11.5 ~ 13V
VOLTAGE ADJ. RANGE Note.6
2.4Vp-p
14.5 ~ 16.2V
1.8Vp-p
19.5 ~ 22V
2.7Vp-p
24 ~ 26V
2.7Vp-p
25 ~ 30V
3.6Vp-p
32.5 ~ 39V
4.6Vp-p
43.6 ~ 51.8V
OUTPUT
Can be adjusted by internal potential meter SVR1
CURRENT ADJ. RANGE Note.6 3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
LOAD REGULATION
SETUP TIME
3.0%
5.0%
1500ms / 230VAC 3000ms / 115VAC at full load
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY(Typ.)
AC CURRENT
Note.5 90 ~ 264VAC
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
83.5% 85% 86.5%
127 ~ 370VDC
INPUT
86.5%
86.5%
87.5%
87.5%
0.55A/115VAC 0.22A/230VAC
40A/230VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
<0.75mA / 240VAC
110% (max)
95 ~ 110%
OVER CURRENT
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
Note.4
SHORT CIRCUIT
OVER VOLTAGE
13.8 ~ 16V
Protection type : Shut down o/p voltage, re-power on to recover
95 10 (TSW1) detect on heatsink of power transistor
17.5 ~ 21V
22.8 ~ 25V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +50 (Refer to output load derating curve)
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
SAFETY &
EMC
Compliance to EN55015
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; En61547, light industry level, criteria A
MTBF
497.8Khrs min. MIL-HDBK-217F (25
181*61.5*35mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.5Kg; 24pcs/13Kg/0.75CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
7. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-45-SPEC 2009-10-01