Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
P
100
F
-O -O
5 6
LFP100F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*1
6Optional
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
R: with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
SN: with Chassis & cover
Please refer to Instruction
manual 6.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFP100F-24-Y
103.2 (206.4)
24V 4.3A (8.6A)
LFP100F-36-Y
100.8 (201.6)
36V 2.8A (5.6A)
LFP100F-48-Y
100.8 (201.6)
48V 2.1A (4.2A)
*2
*2
SPECIFICATIONS
MODEL
LFP100F-24-Y
LFP100F-36-Y
LFP100F-48-Y
*5
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 1.3typ (Io=100%)
ACIN 200V 0.7typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 84.0typ (Io=100%)
ACIN 200V 87.0typ (Io=100%)
ACIN 100V 0.99typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
84.0typ (Io=100%)
87.0typ (Io=100%)
84.0typ (Io=100%)
87.0typ (Io=100%)
EFFICIENCY[%]
INPUT
POWER FACTOR
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
36
48
*2
*7
*7
4.3 (Peak 8.6)
96max
150max
2.8 (Peak 5.6)
144max
240max
150max
200max
250max
300max
360max
450max
144max
2.1 (Peak 4.2)
192max
240max
150max
200max
250max
300max
480max
600max
192max
0 to +50C 120max
-10 - 0C 160max
0 to +50C 150max
-10 - 0C 180max
0 to +50C 240max
*3
RIPPLE[mVp-p]
*3
RIPPLE NOISE[mVp-p]
OUTPUT
TEMPERATURE REGULATION[mV]
-10 to +50
C
290max
96max
*
4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.60 to 27.50
32.40 to 39.60
36.00 to 37.44
39.60 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
24.00 to 24.96
OVERCURRENT PROTECTION Works over 101% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V] 27.60 to 33.60 41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
Not provided
Option (Refer to Instruction Manual 6)
.
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
INPUT-FG
ISOLATION
.
*6
*6
*5
OUTPUT RC-FG
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
IMPACT
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s (20G), 11ms, once each X, Y and Z axis
2
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
SAFETY AND
NOISE
REGULATIONS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
*8
Complies with IEC61000-3-2 (Class A)
62X33X155mm [2.44X1.30X6.10 inches] (WXHXD) / 290g max (with chassis & cover : 480g max)
OTHERS
*5
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 Specification is changed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. And Duty 40% max, refer to Instruction
Manual 5. In detail.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*7 Please contact us about dynamic load and input response.
*8 Please contact us about another class.
*4 Drift is the change in DC output for an eight hour period *
after a half-hour warm-up at 25C, with the input voltage *
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded.
held constant at the rated input/output.
*
Derating is required when operated with chassis and cover.
*3 This is the value that measured on measuring board with *5 Derating is required.
capacitor of 22mF at 150mm from output terminal.
*6 Applicable when remote control (optional) is added.
*
Sound noise may be generated by power supply in case of pulse load.
LFP-2