LES SERIES - 15 WATT
DESCRIPTION
FEATURES
LES DC/DC converters provide up to 15 Watts of output
• Industry Standard Package • 24V and 48V Inputs
power in an industry standard package and footprint. With a • Industry Standard Pinout
maximum case temperature of 100°C, the LES is well suited • 85°C Case Operation
for the most demanding telecom, networking, and industrial • Short Circuit Protection
applications. The LES features 1500 VDC isolation, short
• Input Pi Filter and
6-Sided Shielding
• Regulated Outputs
• 1500V Isolation
circuit, and overtemperature protection, as well as six-sided
shielding. The LES is available with optional enable and
voltage trim. Please see the IAD series for dual-output
applications.
Efficiency vs. Load (24V Input)
85
80
75
70
65
60
55
50
45
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
10
20
30
40
50
60
70
80
90
100
LOAD %
Output
Efficiency vs. Load (48V Input)
Setpoint Accuracy
±1%
0.2% Vout
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
85
0.5% Vout
80
75
70
65
60
55
50
10% Iout Rated
25% Iout
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
2% Vout
500 µs
±10%
LES010ZE
LES015ZG
Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
110 - 150%
200% Iout
OVP Trip Range
OVP Type
115 -140% Vout Nom.
Second Control Loop
10
20
30
40
50
60
70
80
90
100
LOAD %
General
Turn-On Time
10 ms
Positive/Negative Logic
400 kHz
Remote Shutdown
Switching Frequency
Isolation
Notes
†
MTBF predictions may vary slightly from model to model.
Input - Output
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
1500 VDC
500 VDC
0.02 ppm/°C
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
-40 To +100°C
-40 To +125°C
95%
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, cUL, TUV
Storage Range
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.