185W Multiple Channel Output Switching Power Supply LDV-185 series
Features :
180~295VAC input range
Multiple channel with constant current output
Meet 4KV surge immunity level(EN61000-4-5)
Protections: Short circuit / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
IP67 design for indoor or outdoor installations
Optional timer dimming function
High efficiency up to 88%
-40 can power on
Suitable for LED lighting and moving sign applications
3 years warranty
IP67
LDV-185-350A
Blank : IP67 rated. No timer dimming function.
D(option): IP67 rated. Built-in timer dimming function,contact MEAN WELL for details.
SPECIFICATION
MODEL
LDV-185-350A
LDV-185-350B
350mA
LDV-185-350C
LDV-185-700A
LDV-185-700B
LDV-185-700C
SINGELE CHANNEL
RATED CURRENT
350mA
700mA
350mA
700mA
35~40V
700mA
30 ~ 35V
147W
35 ~ 40V
40 ~ 48V
185W
30~35V
147W
6CH
40~48V
185W
6CH
DC VOLTAGE RANGE Note 5.
RATED POWER(max.) Note 3.
168W
12CH
168W
6CH
OUTPUT
MAX CHANNEL
SETUP, RISE TIME
HOLD UP TIME
Note 3 12CH
12CH
Note 2.
2500ms, 50ms
10ms / 230VAC
5%
CONSTANT CURRENT ACCURACY
VOLTAGE RANGE
180~ 295VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR
PF>0.95/230VAC
PF>0.92/277VAC at full load(please refer to Power Factor Characteristic Curve)
INPUT
EFFICIENCY (Typ.)
AC CURRENT
Note 4. 88%
1.5A/230VAC
1.0A/277VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SHORT CIRCUIT
COLD START 60A/230VAC
<0.75mA / 240VAC
Channel shut down when each channel fault, re-power on to recovery
41 ~ 50V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
100 10 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
When the NTC (RTH3) temperature is higher than 90 10 PSU will enter dimming mode with decreasing output current
47 ~ 50V
54 ~ 63V
41~50V
47~50V
54~63V
OVER VOLTAGE
PROTECTION
OVER TEMPERATURE
OTP DIMMING
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to Derating curve ),-40 can power on
20 ~ 95% RH non-condensing
ENVIRONMENT
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
IP67 approved; Design refer to EN61347-1,EN61347-2-13,UL8750
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC 1minute
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
Compliance to EN55015,EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
198.2Khrs min. MIL-HDBK-217F (25
222.2*90*38.8mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.27 Kg; 12pcs/16.2Kg/1.02CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
3. Please do not exceed the rated power when choosing channel quantity and voltage range(350C/700C model).
4. Efficiency is measured under 230VAC input with Pout>120W and each output channel connecting with the same quantity of LEDs(similar Vf sum).
5. DC output voltage is measured between LED.•DE~«L
ehytdetcfelbiecnamrbofeCpMeacni.wtnempiuqSleaniEhtinoitanibmondetfarewplbitahnceiopwmsatdoerdisnocyilpursceawoeh.6Tp
.niagnoitaltsnetlpmaoehnevitceriCDMyEfilcautqo-etsumreutrcafunatnempiuqlemanieh,noitaltsnetflpmoci
File Name:LDV-185-SPEC 2011-12-06