Ordering information
AC-DC Power Supplies Open Frame/Enclosed type
LDA 10
F
-5
-O
5
LDA10F
1
2
3
4
1Series name
R
Recommended EMI/EMC Filter
2Output wattage
3Universal input
4Output voltage
5Optional *2
NAC-06-472
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA10F-3
6
3V 2.0A
LDA10F-5
10
5V 2.0A
LDA10F-12
10.8
12V 0.9A
LDA10F-15
10.5
15V 0.7A
LDA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
LDA10F-3
LDA10F-5
LDA10F-12
LDA10F-15
LDA10F-24
VOLTAGE[V]
AC85 - 264 1 or DC110 - 370
f
(
(
)
)
ACIN 100V 0.25typ Io=100%
CURRENT[A]
ACIN 200V 0.16typ Io=100%
LDA
FREQUENCY[Hz]
INPUT
47 - 440 or DC
68typ
EFFICIENCY[%]
72typ
74typ
74typ
78typ
(
(
) (
) (
)
)
ACIN 100V 15typ Io=100% At cold start
INRUSH CURRENT[A]
ACIN 200V 30typ Io=100% At cold start
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max 60Hz According to UL CSA VDE and DEN-AN
3
5
12
15
24
CURRENT[A]
2
2
0.9
0.7
0.5
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
20max
48max
100max
120max
160max
150max
180max
120max
48max
60max
120max
120max
160max
150max
180max
150max
60max
96max
150max
120max
160max
150max
180max
240max
96max
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV] 50max
1
*
DRIFT[mV]
20max
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
200max ACIN 100V Io=100%
(
,
)
(
,
)
(
,
)
10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100% 100typ ACIN 200V Io=100%
(
,
,
,
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
Fixed "Y"which can be adjusted the output is available as option :5 12 15 24V 10%
t
OUTPUT VOLTAGE SETTING[V]
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
,
Works over 115% of rating by zener diode clamping
OVERVOLTAGE PROTECTION 4.00V min
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
,
,
,
(
)
)
)
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
ISOLATION INPUT-FG
OUTPUT-FG
,
,
(
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
W
,
,
,
(
(
) (
)
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
IMPACT
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
SAFETY AND
NOISE
, , ,
UL60950-1 EN60950-1 EN50178 CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
,
,
,
Complies with FCC-B CISPR22-B EN55022-B VCCI-B
REGULATIONS
( )
50 21 105mm W H
X X
(
)
D /75g max without chassis and cover
X
X
OTHERS
Convection
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*2 Please contact us about safety approvals for the model with option.
*
*
*
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
June 29, 2011
LDA-2