Ordering information
AC-DC Power Supplies Open Frame/Enclosed type
LC
A
10
S
-5
-O
6
LCA10S
1
2
3
4
5
1Series name
Recommended EMI/EMC Filter
NAC-06-472
R
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional *3
C :with Coating
G :Low leakage current
Y :with Potentiometer
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
LCA10S-5
10
LCA10S-5-H
10
LCA10S-12
10.8
LCA10S-15
10.5
LCA10S-24
12
MAX OUTPUT WATTAGE[W]
DC OUTPUT
5V 2A
5V 2A
12V 0.9A
15V 0.7A
24V 0.5A
SPECIFICATIONS
MODEL
LCA10S-5
LCA10S-5-H
LCA10S-12
LCA10S-15
LCA10S-24
VOLTAGE[V]
CURRENT[A]
AC85 - 132 1 or DC110 - 170
f
(
)
ACIN 100V 0.3typ Io=100%
FREQUENCY[Hz]
INPUT
47 - 440 or DC
71typ
EFFICIENCY[%]
71typ
75typ
75typ
78typ
(
)
INRUSH CURRENT[A] ACIN 100V 25typ Io=100%
(
,
,
)
LEAKAGE CURRENT[mA] 0.5max 60Hz According to UL CSA and DEN-AN
LCA
VOLTAGE[V]
CURRENT[A]
5
2
5
12
15
24
(
)
2 Peak 3
0.9
0.7
0.5
LINE REGULATION[mV] 20max
LOAD REGULATION[mV] 40max
20max
48max
100max
120max
160max
150max
180max
120max
48max
60max
120max
120max
160max
150max
180max
150max
60max
96max
150max
120max
160max
150max
180max
240max
96max
40max
1
*
1
*
1
*
1
*
0 to +50
80max
80max
C
RIPPLE[mVp-p]
-10 - 0
140max
120max
160max
140max
120max
160max
50max
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV] 50max
2
*
DRIFT[mV]
20max
20max
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
100max ACIN 85V Io=100%
(
,
)
(
,
)
10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100%
(
,
,
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed "Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12 15 24V 10%
t
OUTPUT VOLTAGE SETTING[V] 4.9 - 5.3
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
(
)
OVERCURRENT PROTECTION Works over 105% of rating works over 105% of peak current at option -H and recovers automatically
,
OVERVOLTAGE PROTECTION Works over 115% of rating by zener diode clamping
PROTECTION
CIRCUIT AND OPERATING INDICATION Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
Not provided
Not provided
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
ISOLATION INPUT-FG
OUTPUT-FG
,
,
(
)
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
W
,
,
,
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
IMPACT
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
SAFETY AND
NOISE
,
UL60950-1 CSA C22.2 No.60950-1 Complies with DEN-AN
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
,
Complies with FCC-B VCCI-B
REGULATIONS
(
)
H D / 65g max
X X
49 17 94mm W
X
X
OTHERS
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
*3 Please contact us about safety approvals for the model with option.
*
Avoid prolonged use under over-load.