Current Transducer LA 55-P
IPN = 50 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16019
Electrical data
IPN
IPM
RM
Primary nominal current rms
Primary current, measuring range
Measuring resistance @
50
0 .. ± 70
TA = 70°C
RM miniRM maxi RM miniRM maxi
A
A
Features
TA = 85°C
· Closed loop (compensated) current
transducer using the Hall effect
· Printed circuit board mounting
· Isolated plastic case recognized
according to UL 94-V0.
with ± 12 V
with ± 15 V
@ ± 50 A maxi
10 100 60 95
10 50
50 160 135 155
50 90 1352) 1352)
W
W
W
W
@ ± 70 A maxi
@ ± 50 A maxi
@ ± 70 A maxi
601) 601)
Advantages
ISN
KN
VC
IC
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
50
1 : 1000
± 12 .. 15
10(@±15 V)+IS mA
2.5
mA
· Excellent accuracy
· Very good linearity
V
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
Vd
kV
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C
@ ± 15 V (± 5 %)
@ ± 12 .. 15 V (± 5 %)
± 0.65
± 0.90
< 0.15
%
%
%
· Current overload capability.
e
Linearity error
L
Typ Maxi
Applications
IO
IOM
Offset current @ IP = 0, TA = 25°C
Magnetic offset current 3) @ IP = 0 and specified RM
after an overload of 3 x IPN
± 0.2 mA
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
± 0.3 mA
± 0.1 ± 0.5 mA
± 0.1 ± 0.6 mA
IOT
Temperature variation of IO
0°C .. + 70°C
- 25°C .. + 85°C
tra
tr
Reaction time @ 10 % of IPN
Response time @ 90 % of IPN Step
< 500
< 1
ns
µs
di/dt di/dt accurately followed
BW Frequency bandwidth (- 1 dB)
> 200
DC .. 200
A/µs
kHz
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications.
General data
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
- 25 .. + 85
- 40 .. + 90
80
85
18
°C
°C
W
W
g
Application Domain
TA = 70°C
TA = 85°C
· Industrial.
m
Mass
Standards
EN 50178: 1997
1)
Notes:
Measuring range limited to ± 60 A maxi
Measuring range limited to ± 55 A maxi
Result of the coercive field of the magnetic circuit.
2)
3)
page1/2
070103/11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.