5秒后页面跳转
LA205-S_11 PDF预览

LA205-S_11

更新时间: 2024-10-29 01:22:43
品牌 Logo 应用领域
莱姆 - LEM /
页数 文件大小 规格书
3页 372K
描述
Current Transducer

LA205-S_11 数据手册

 浏览型号LA205-S_11的Datasheet PDF文件第1页浏览型号LA205-S_11的Datasheet PDF文件第2页 
Dimensions LA 205-S (in mm)  
Connection  
Mechanical characteristics  
Remarks  
● General tolerance  
● Transducer fastening  
± 0.5 mm  
2 holes Ø 5.5 mm  
2 M5 steel screws  
IS is positive when IP flows in the direction of the arrow.  
Temperature of the primary conductor should not exceed  
100°C.  
Recommended fastening torque 1.2 Nm  
● Dynamic performances (di/dt and response time) are best  
with a single bar completely filling the primary hole.  
● This is a standard model. For different versions (supply  
voltages, turns ratios, unidirectional measurements...),  
please contact us.  
● Primary through-hole  
22.7 x 17.4 mm  
● Connection of secondary  
MOLEX 5046 4 pins  
tin plated  
Page 3/3  
www.lem.com  
110126/9  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.