Current Transducer LA 200-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 200 A
16044
Electrical data
Features
IPN
IPM
RM
Primary nominal current rms
Primary current, measuring range
Measuring resistance @
200
0 .. ± 300
TA = 70°C TA = 85°C
RM minRM max RM minRM max
A
A
● Closed loop (compensated)
current transducer using the Hall
effect
● Printed circuit board mounting
● Isolated plastic case recognized
according to UL 94-V0.
with ± 12 V
with ± 15 V
@ ± 200 A max
@ ± 250 A max
@ ± 200 A max
@ ± 300 A max
0
0
0
0
30
8
60
12
0
0
0
0
26
4
56
8
Ω
Ω
Ω
Ω
ISN
KN
VC
IC
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
100
1 : 2000
± 12 .. 15
16 (@ ± 15 V) + IS mA
mA
Advantages
● Excellent accuracy
● Very good linearity
V
● Low temperature drift
● Optimized response time
● Wide frequency bandwidth
● No insertion losses
● High immunity to external
interference
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C
@ ± 15 V (± 5 %)
± 0.40
± 0.65
< 0.15
Typ
%
%
%
@ ± 12 .. 15 V (± 5 %)
ε
Linearity error
L
● Current overload capability.
Max
IO
IOM
Offset current @ IP = 0, TA = 25°C
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 x IPN
± 0.20
mA
Applications
± 0.25
mA
mA
mA
ns
µs
A/µs
kHz
● AC variable speed drives and
servo motor drives
● Static converters for DC motor
drives
● Battery supplied applications
● Uninterruptible Power Supplies
(UPS)
IOT
Temperature variation of IO
0°C .. + 70°C
± 0.10 ± 0.25
± 0.15 ± 0.55
< 500
- 40°C .. + 85°C
Reaction time to 10 % of IPN step
Response time 2) 3) to 90 % of IPN step
tra
tr
< 1
> 200
di/dt di/dt accurately followed 3)
BW
Frequency bandwidth (- 1 dB)
DC .. 100
● Switched Mode Power Supplies
(SMPS)
General data
● Power supplies for welding
applications.
TA
TS
RS
ꢀ
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
- 40 .. + 85
- 40 .. + 90
76
80
40
°C
°C
Ω
Ω
g
Application domain
TA = 70°C
TA = 85°C
ꢀ
ꢀ
● Industrial.
m
Mass
Standards
EN 50178: 1997
Notes: 1) The result of the coercive field of the magnetic circuit
2)
With a di/dt of 100 A/µs
3)
The primary conductor is best filling the through-hole and/or the return of
the primary conductor is above the top of the transducer.
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
090508/15
www.lem.com