Current Transducer LA 125-P
IPN = 125 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16030
Electrical data
Features
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
125
0 .. ± 200
TA = 70°C
RM min RMmax RM min RMmax
A
A
· Closed loop (compensated) current
transducer using the Hall effect
· Printed circuit board mounting
· Insulated plastic case recognized
according to UL 94-V0.
TA = 85°C
with ± 12 V
with ± 15 V
@ ± 125 A max
5
5
52
20
25 74
25 34
14 50
14 18
40 72
401) 401)
W
W
W
W
@ ± 200 A max
@ ± 125 A max
@ ± 200 A max
Advantages
ISN
KN
VC
IC
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
125
1 : 1000
± 12 .. 15
16(@ ±15 V)+IS mA
mA
· Excellentaccuracy
· Very good linearity
V
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
Vd
3
kV
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C
@ ± 15 V (± 5 %)
± 0.60
± 0.80
< 0.15
%
%
%
@ ± 12 .. 15 V (± 5 %)
e
Linearity error
· Current overload capability.
L
Typ Max
Applications
IO
IOM
IOT
Offset current @ IP = 0, TA = 25°C
± 0.40 mA
± 0.50 mA
± 0.15 ± 0.50 mA
± 0.30 ± 0.95 mA
Residual current2) @ IP = 0, after an overload of 3 xIPN
· AC variable speed drives and servo
motor drives
Thermal drift of IO
0°C .. + 70°C
- 40°C .. + 85°C
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
· Switched Mode Power Supplies
(SMPS)
tra
tr
Reaction time @ 10 % of IPN
< 500
< 1
> 200
DC .. 100
ns
µs
A/µs
kHz
Response time 3) 4) @ 90 % of IPN
di/dt di/dt accurately followed4)
f
Frequency bandwidth4) (- 1 dB)
General data
· Power supplies for welding
applications.
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
- 40 .. + 85
- 40 .. + 90
32
33.5
40
°C
°C
W
W
g
TA = 70°C
TA = 85°C
m
Mass
Standards
EN 50178 : 1997
1)
Notes : Measuring range limited to ± 180 A max
2)
The result of the coercive field of the magnetic circuit.
With a di/dt of 100 A/µs
The primary conductor is best filling the through-hole and/or the return
of the primary conductor is above the top of the transducer.
3)
4)
060213/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
page1/2
LEM
www.lem.com