5秒后页面跳转
L2PA-50-B/Q PDF预览

L2PA-50-B/Q

更新时间: 2024-10-30 02:19:51
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 104K
描述
Power Transducer Series L-UNIT

L2PA-50-B/Q 数据手册

 浏览型号L2PA-50-B/Q的Datasheet PDF文件第2页浏览型号L2PA-50-B/Q的Datasheet PDF文件第3页 
MODEL: L2PA  
J: 0 – 5 mA DC (Load resistance 2000 Ω max.)  
Power Transducer Series L-UNIT  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
DUAL PT TRANSDUCER  
(Average sensing, RMS calibrated)  
Functions & Features  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Converting an alternating voltage from a potential  
(voltage) transformer into a standard process signal  
• 2 transducers housed in one enclosure  
• Minimum ripple  
• Isolation up to 2000 V AC  
• High-density mounting  
[3] AUXILIARY POWER SUPPLY  
AC Power  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
DC Power  
R: 24 V DC  
V: 48 V DC  
Typical Applications  
• Centralized monitoring and control of power line and  
power supply voltages measured at switch boards  
• Monitoring abnormal voltage drops for detecting overload  
75  
(2.95)  
75  
(2.95)  
112  
(4.41)  
[4] OPTIONS  
mm (inch)  
blank: none  
/Q: With options (specify the specification)  
MODEL: L2PA–[1][2]–[3][4]  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
ORDERING INFORMATION  
• Code number: L2PA–[1][2]-[3][4]  
Specify a code from below for each [1] through [4].  
(e.g. L2PA-5A-C/Q)  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
GENERAL SPECIFICATIONS  
Construction: Stand-alone; terminal access at the front  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
[1] INPUT  
Voltage  
5: 0 – 150 V AC  
6: 0 - 300 V AC  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to auxiliary power, between  
channels  
[2] OUTPUT  
Input waveform: Sine wave  
Current  
Overrange output: 0 to 120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
A: 4 – 20 mA DC (Load resistance 500 Ω max.)  
D: 0 – 20 mA DC(Load resistance 500 Ω max.)  
E: 0 – 16 mA DC (Load resistance 625 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1000 Ω max.)  
G: 0 – 1 mA DC (Load resistance 10 kΩ max.)  
http://www.m-system.co.jp/  
L2PA SPECIFICATIONS  
ES-1988 Rev.6 Page 1/3  

与L2PA-50-B/Q相关器件

型号 品牌 获取价格 描述 数据表
L2PA-50-C MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-C/Q MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-D MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-D/Q MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-F MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-F/Q MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-G MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-G/Q MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-H MSYSTEM

获取价格

Power Transducer Series L-UNIT
L2PA-50-H/Q MSYSTEM

获取价格

Power Transducer Series L-UNIT