Plug-in Signal Conditioners K-UNIT

KWRS2-61D-B/BL 数据手册

 浏览型号KWRS2-61D-B/BL的Datasheet PDF文件第2页浏览型号KWRS2-61D-B/BL的Datasheet PDF文件第3页 
MODEL: KWRS2  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
5: Pt 50 Ω (JIS'81)  
Plug-in Signal Conditioners K-UNIT  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)  
6: Ni 508.4 Ω  
RTD TRANSMITTER  
(CE, two isolated outputs)  
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)  
0: Specify  
Functions & Features  
• Accepting direct input from an RTD and providing  
two standard process signals  
Note: Consult M-System for 2-wire RTD  
• Linearization  
[2] OUTPUT 1  
• Burnout protection  
Current  
• "Active bridge" circuit containing two constant current  
sources allows large leadwire resistances up to 200 Ω  
• Fast response type available  
• High-density mounting  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
Typical Applications  
• Long distance transmission between the RTD and the  
transmitter  
• Combination with intrinsic safety barriers  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
72  
(2.83)  
80  
(3.15)  
K-U  
N
IT  
132  
(5.20)  
[3] OUTPUT 2  
mm (inch)  
Current  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
MODEL: KWRS2–[1][2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: KWRS2-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. KWRS2-4AA-H/BL/Q)  
• Temperature range (e.g. 0 – 500°C)  
• Special output ranges (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Same range availability as Output 1  
[4] POWER INPUT  
AC Power  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
[1] INPUT RTD (2- or 3-wire)  
1: JPt 100 (JIS'89)  
DC Power  
S: 12 V DC  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)  
3: Pt 100 (JIS'89)  
R: 24 V DC  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
4: Pt 100 (JIS'97, IEC)  
KWRS2 SPECIFICATIONS  
ES-3519 Rev.7 Page 1/3  
https://www.m-system.co.jp/  

与KWRS2-61D-B/BL相关器件

型号 品牌 获取价格 描述 数据表
KWRS2-61D-B/K MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-B/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-C MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-C/BL MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-C/K MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-C/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-D MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-D/BL MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-D/K MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KWRS2-61D-D/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT