5秒后页面跳转
KRS-56-J PDF预览

KRS-56-J

更新时间: 2024-10-28 02:21:27
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 100K
描述
Plug-in Signal Conditioners K-UNIT

KRS-56-J 数据手册

 浏览型号KRS-56-J的Datasheet PDF文件第2页浏览型号KRS-56-J的Datasheet PDF文件第3页 
MODEL: KRS  
Note: Consult M-System for 2-wire RTD  
Plug-in Signal Conditioners K-UNIT  
[2] OUTPUT  
Current  
RTD TRANSMITTER  
(CE, isolated)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
Functions & Features  
• Accepting direct input from an RTD and providing a  
standard process signal  
• Linearization  
• Burnout protection  
• "Active bridge" circuit containing two constant current  
sources allows large leadwire resistances up to 200 Ω  
• Fast response type available  
• High-density mounting  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 3000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Typical Applications  
• Long distance transmission between the RTD and the  
transmitter  
• Combination with intrinsic safety barriers  
50  
(1.97)  
[3] POWER INPUT  
AC Power  
80  
(3.15)  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
123  
(4.84)  
DC Power  
mm (inch)  
S: 12 V DC  
R: 24 V DC  
MODEL: KRS–[1][2]–[3][4]/CE  
[4] OPTIONS (multiple selections)  
Response Time (0 – 90 %)  
blank: Standard (≤ 0.5 sec.)  
/K: Fast Response (Approx. 25 msec.)  
Burnout  
ORDERING INFORMATION  
• Code number: KRS-[1][2]-[3][4]/CE  
Specify a code from below for each of [1] through [4].  
(e.g. KRS-4A-H/BL/CE)  
blank: Upscale burnout  
• Temperature range (e.g. 0 – 500°C)  
• Special output range (For codes Z & 0)  
/BL: Downscale burnout  
Standards & Approvals (must be specified)  
/CE: CE marking  
[1] INPUT RTD (2- or 3-wire)  
1: JPt 100 (JIS'89)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)  
3: Pt 100 (JIS'89)  
Connection: M3.5 screw terminals  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
4: Pt 100 (JIS'97, IEC)  
Screw terminal: Chromated steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
5: Pt 50 Ω (JIS'81)  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
At burnout: Downscale ≤ -10 %, Upscale ≥ 110 %  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)  
6: Ni 508.4 Ω  
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)  
0: Specify  
KRS SPECIFICATIONS  
ES-3521-CE Rev.4 Page 1/3  
https://www.m-system.co.jp/  

与KRS-56-J相关器件

型号 品牌 获取价格 描述 数据表
KRS-56-J/BL MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-J/CE MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-J/K MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-R MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-R/BL MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-R/CE MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-R/K MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-S MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-S/BL MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KRS-56-S/CE MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT