High Capacitance for General Use KRM Series Specifications and Test Methods
No.
1
Item
Operating
Specifications
X5R Char.: ꢀ55 to +85°C
X6S Char.: ꢀ55 to +105°C
X7R Char.: ꢀ55 to +125°C
Test Method
Reference temperature: 25°C
Temperature Range
2
3
Appearance
Dimensions
No defects or abnormalities
Visual inspection
Within the specified dimensions
Using calipers and micrometers
No failure should be observed when voltage in the table is
applied between the terminations for 1 to 5 sec., provided the
charge/discharge current is less than 50mA.
Rated Voltage
DC16V, DC25V, DC35V,
DC50V, DC63V
DC100V, DC250V
DC630V
Test Voltage
4
Dielectric Strength No defects or abnormalities
250% of the reted voltage
200% of the reted voltage
150% of the reted voltage
120% of the reted voltage
DC1000V
[KRM21, KRM31]
W.V.: 16V/25V/35V
: More than 50MΩ · μF
Insulation Resistance
W.V.: 50V/100V
(I.R.)
The insulation resistance should be measured with Rated
Voltage and within 60 5 sec. of charging.
5
6
: More than 500MΩ · μF
[KRM55]
More than 100MΩ · μF
Capacitance
Within the specified tolerance
The capacitance/D.F. should be measured at reference
temperature at the meaning frequency and voltage shown in
the table.
[KRM21, KRM31]
W.V.: 16V/25V/35V
: 0.15 max.
W.V.: 50V
: 0.025 max.
W.V.: 100V
: 0.05 max.
[KRM55]
Nominal
Measuring
Measuring
Voltage
AC0.5 0.1V(r.m.s.)
AC1.0 0.2V(r.m.s.)
Dissipation
Factor (D.F.)
7
Capacitance Frequency
C>10μF
CV10μF
120 24ꢁH
1 0.2kꢁH
0.025 max.
The capacitance measurement should be made at each step
specified in the Table.
Step
Temperature (°C)
25 2
Min. Operating Temp.
25 2
Max. Operating Temp.
25 2
1
2
3
4
5
3
Capacitance
Temperature
Characteristics
X5R Char.: Within 15% (Temp. Range: ꢀ55 to +85°C)
X6S Char.: Within 22% (Temp. Range: ꢀ55 to +105°C)
X7R Char.: Within 15% (Temp. Range: ꢀ55 to +125°C)
8
2
U*ÀiÌÀi>ÌiÌ
Perform a heat treatment at 150+0/–10°C for 60 5 min. and
then let sit for 24 2 hrs. at room condition. (*1)
A static load of 10N using a pressure rod should be applied to
the center in the direction of the arrow and held for 10 s.
Pressure Rod
Pressure
Strength of Metal
Terminal
R 0.5
9
Termination not to be broken or loosened
0.5L
Solder the capacitor to the testing jig (glass epoxy board) shown
in Fig. 1.
Then apply 10N force in the direction of the arrow.
The soldering should be done using the reflow method and
should be conducted with care so that the soldering is uniform
and free defects such as heat shock.
Adhesive Strength
of Termination
10
No removal of the terminations or other defect should occur.
10N, 10T1s
Glass Epoxy Board
Fig. 1
(*1) "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
Continued on the following page.