COUNT
DESCRIPTION OF REVISIONS
RE-5-1618
DATE
COUNT
DESCRIPTION OF REVISIONS
RE-5-2288
DATE
BY CHKD
BY CHKD
1
N.J.W A.B.H 17.03.15
Y.K.G A.B.H 17.12.12
1
2
K.C.J A.B.H 19.09.11
K.C.J A.B.H 23.01.11
3
4
1
2
10
RE-5-1840
RE-5-2935
APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
STORAGE
TEMPERATURE RANGE
-40℃ ~ 85℃ (NOTE1)
-10℃ TO 60℃(WITH PACKING)
4
4
RATING
VOLTAGE
AC 10V
0.5A
OPERATING OR
STORAGE HUMIDITY RANGE
95% MAXIMUM
(NON-CONDENSING)
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT
ACCORDING TO DRAWING
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
IEC60512-2-1
OPEN VOLTAGE 20 mV AC MAX
TEST CURRENT 1mA
INITIALLY 100mΩ MAXIMUM (NOTE2)
INITIALLY 1000MΩ MINIMUM
X
-
1
2
INSULATION RESISTANCE MEASURE WITHIN 1 MINUTE AFTER APPLYING
500V DC
X
X
-
X
IEC60512-3-1
2
VOLTAGE PROOF
IEC60512-4-1
① NO FLASHOVER OR BREAKDOWN
② CURRENT LEAKAGE 1mA MAXIMUM
500Vrms AC IS APPLIED FOR 1 MINUTE
2
MECHANICAL CHARACTERISTICS
3,000 TIMES INSERTION AND WITHDRAWAL
SHALL BE MADE AT THE CYCLE RATE LESS
THAN 10 CYCLES PER 1MINUTE
NOTE : AFTER EACH 10 CYCLES STOP THE
INSERTION AND REST THE CONNECTOR
① CONTACT RESISTANCE:
AFTER TEST 50mΩ MAXIMUM CHANGE
MECHANICAL OPERATION FOR 5 TO 10 MINUTES.
[OFFICE ENVIRONMENT]
EIA364B class 1.1
X
-
CARD SURFACE SHALL BE CLEANED BY AIR
BLOW:
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
AT EACH 100 CYCLES INTERVAL(10 TIMES)
FROM START TO 1,000 CYCLES.
d
AT EACH 1,000 CYCLES INTERVAL(2 TIMES)
FROM 1,001 CYCLES TO 3,000 CYCLES.
TRAY MATING FORCE
TRAY UNMATING FORCE
TRAY EJECTION FORCE
10N MAX (NOTE3)
3N MIN (NOTE3)
15N MAX (NOTE3)
MEASURED BY APPLICABLE CARD AT 25±
3mm/min
X
X
X
-
-
-
VIBRATION AND HIGH
FREQUENCY
IEC60512-6-4
FREQUENCY 10 TO 55 TO 10 Hz/min, SINGLE ① NO ELECTRICAL DISCONTINUITY OF 1us
AMPLITUDE 0.75mm FOR 4h IN X,Y,Z 3
DIRECTIONS, TOTAL 12h
② NO MECHANICAL DAMAGE SHALL OCCUR ON THE
PARTS.
2
2
ACCELERATION 490m/s2 STANDARD HOLDING
TIME 11ms, SEMI-SINE WAVE FOR 3 TIMES IN 3 ③ CONTACT RESISTANCE
DIRECTIONS, TOTAL 18 TIMES. AFTER TEST 50mΩ MAXIMUM CHANGE
SHOCK
IEC60512-6-3
REFERENCE DRAWING
REMARKS
DRAWN
DESIGNED
CHECKED
APPROVED
RELEASED
(NOTE1) : INCLUDE THE TEMPERATURE RISE BY CURRENT
(NOTE2) : CONTACT RESISTANCE INCLUDES CONDUCTOR RESISTANCE UNLESS
OTHERWISE SPECIFIED. THE TEST SHOULD BE DONE UNDER TEMP 15 TO 35℃.
AIR PRESSURE 86 TO 106kPA, RESLATIVE HUMIDITY 25 TO 85%.
(NOTE3) : IT MAY BE CHANGED ACCORDING TO THE TRAY/CARD MATERIAL AND
DIMENSIONS.
ENG
W.S.YOON
16.06.09
W.S.YOON
16.06.09
B.H.AN
16.06.09
H.C.SONG
16.06.09
23.01.11
DEPT
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST X: APPLICABLE TEST
PART NO.
KP15TL-SF(800)
HIROSE KOREA CO.,LTD.
CODE NO.(OLD) DRAWING NO.
CL ELC4-632045
SPECIFICATION SHEET
CODE NO.
CL 6538-0007-3-800
1
2