Ordering information
AC-DC Power Supplies DIN Rail Type
KLO A 120
F -OO -O
KLEA/KLNA120F
1
2
3
4
5
6
1
Series name
Example recommended EMI/EMC filter
NAC-04-472-D
R
KLE : Euro Style I/O Terminals
KLN : Barrier Blocks Style
I/O Terminals
2
3
4
5
6
Single output
Output wattage
Universal input
Output voltage
Option
UL508
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
C : with Coating
N2: Screw mounting
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
KLEA/KLNA120F-24
120
24V 5A
KLEA/KLNA120F-48
120
48V 2.5A
SPECIFICATIONS
MODEL
KLEA/KLNA120F-24
KLEA/KLNA120F-48
*
9
VOLTAGE[V]
AC85 - 264 1f(Output derating is required)
ACIN 115V 1.2typ
ACIN 230V 0.6typ
CURRENT[A]
FREQUENCY[Hz]
50 / 60 (45 - 66)
ACIN 115V 86.5typ
EFFICIENCY[%]
INPUT
ACIN 230V 88.0typ
ACIN 115V 0.98typ
ACIN 230V 0.90typ
POWER FACTOR
ACIN 115V 20typ (Io=100%)(at cold start Ta=25
ACIN 230V 40typ (Io=100%)(at cold start Ta=25
C
C
)
)
INRUSH CURRENT[A]
*
1
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
48
CURRENT[A]
5
2.5
*
*
2
2
*
8
*
8
LINE REGULATION[mV]
LOAD REGULATION[mV]
96max (Io=30-100%)
192max (Io=30-100%)
*
8
*
8
150max (Io=30-100%)
300max (Io=30-100%)
150max
0 to +70C 150max
*
3
RIPPLE[mVp-p]
-20 - 0C
240max
240max
Io=0 - 30% 500max
0 to +70C 180max
650max
180max
*
3
OUTPUT
RIPPLE NOISE[mVp-p]
-20 - 0C
300max
300max
Io=0 - 30% 500max
0 to +70C 240max
-20 to +70C 290max
650max
480max
600max
TEMPERATURE REGULATION[mV]
*
4
96max
DRIFT[mV]
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
500typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
21.60 to 26.40
24.00 to 24.96
Works over 105% of rating and recovers automatically
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
43.20 to 52.80
48.00 to 49.92
PROTECTION
CIRCUIT AND OVERVOLTAGE PROTECTION[V] 27.60 to 33.60
54.00 to 67.20
OTHERS
DC_OK LAMP
LED (Green)
INPUT-OUTPUT
INPUT-PE
OUTPUT-PE
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
W
min
min
min
(
(
At Room Temperature
At Room Temperature
)
)
ISOLATION
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
(
At Room Temperature
)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +70
-30 to +85
C
C
, 20 - 90%RH (Non condensing), Type tested for -40C
start-up (Derating is required)
, 20 - 90%RH (Non condensing)
ENVIRONMENT
2
*
7
6
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail)
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis (Packing state)
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE
UL60950-1, C-UL (CSA60950-1), EN60950-1, UL508, Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*
5
Complies with IEC61000-3-2
38 124 117mm (W D) [1.5
580g max
Convection
(
Class A)
*
X
X
X
HX
X
4.88X4.61 inches]
OTHERS
WEIGHT
COOLING METHOD
*
1
The value is primary surge. The current of input surge to a built-in EMI/EMC
Filter(0.2ms or less)is excluded.
*
4
Drift is the change in DC output for an eight hour period after a half-hour
*
*
*
*
8
9
Burst operation at 30% load or less.
warm-up at 25
C
, with the input voltage held constant at the rated input/
Please contact us about DC input voltage.
*
*
2
3
Please contact us about dynamic load and input response.
output.
To meet the specifications. Do not operate over-loaded condition.
A sound may occur from power supply at light or peak loading.
This is the value that measured on measuring board with capacitor of 22
mF
*
*
*
5
6
7
Please contact us about another class.
and 0.1
m
F at 150mm from output terminal.
Case size contains neither the umbo.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM103).
Only as standard mounting orientation (A). Refer to the instruction manual 4.1.
If install other than standard mounting orientation (A), please fix the power
supply for withstand the vibration and impact.
Please refer to the instruction manual 2.5.
KL-2