EZ- LIGHT Touch K30 Series Pick-to-Light
Datasheet
Compact, Single-Point Devices for Error-Proofing of Bin-Picking Operations
•
Rugged, cost-effective and easy-to-install solutions for error-proofing and parts-
verification applications
•
•
Compact devices are completely self contained—No controller needed
Illuminated dome provides an easy-to-see green job light: some models also light
red for alternate operation
•
•
•
•
Waterproof IP69K construction for washdown environments
Easy actuation—no force required
12 V dc to 30 V dc operation
Can be actuated with bare hands or in gloves
Models
1
Model
Function
Output
PNP, NO
PNP, NC
NPN, NO
NPN, NC
PNP, NO
PNP, NC
NPN, NO
NPN, NC
PNP, NO
PNP, NC
NPN, NO
NPN, NC
Connection
Job Light
K30APTGXDQ
K30RPTGXDQ
K30ANTGXDQ
K30RNTGXDQ
K30APTGRCQ
K30RPTGRCQ
K30ANTGRCQ
K30RNTGRCQ
K30APTGREQ
K30RPTGREQ
K30ANTGREQ
K30RNTGREQ
•
•
Job light is ON at all times while job input is active
Touch activates output
Green
•
•
Job light is Green while job input is active
Touch activates output and overrides job light
(turns Red) for visual verification that action was
sensed
Integral 4-pin M12/
Euro-style male quick
disconnect
Green (Red)
Green (Red)
•
Job light is Green at all times while job input is
active
Touch activates output
A touch while job input is inactive causes unit to
light Red, providing visual verification that sensor
is functioning properly
•
•
Wiring Diagrams
NPN
PNP
Color Key
1 = Brown
2 = White
3 = Blue
1
1
3
+
+
12-30V dc
–
12-30V dc
–
3
4
2
4 = Black
4
Load
Load
2
Job Light
Enable > 7V dc
Job Light
Enable < 1.0V dc
NOTE: Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are functionally identical.
1
Integral quick disconnect models are listed.
•
•
To order the 2 m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K30APTGXD.
To order the 150 mm (6 in) PVC cable model with a 4-pin M12/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model
number. For example, K30APTGXDQP .
•
Models with a quick disconnect require a mating cordset.
Original Document
170454 Rev. E
21 November 2016
170454