EZ-LIGHT Touch Gen 2 K30 Series Pick-to-Light
Datasheet
Compact, Single-Point Devices for Error-Proofing of Bin-Picking Operations
•
•
Excellent immunity to false triggering by water spray, detergents, oils, and other foreign materials
Rugged, cost-effective and easy-to-install solutions for error-proofing and parts-verification
applications
•
•
•
•
•
•
•
Compact devices are completely self-contained, no controller needed
Waterproof IEC IP69K construction for washdown environments
Easy actuation, no force required
12 V dc to 30 V dc operation
Can be actuated with bare hands or gloves
Five color options available
Terminal connection models available for panel wiring applications
Models
Job Light
Activation
Method
Color Color
Family Output State Input/Output
1
2
Function
Connection
K30
A
P
T2
G
R
C
Q
A = Normally
Open
P = PNP
N = NPN
T2 = Touch
G = Green
R = Red
Y = Yellow
B = Blue
W = White
X = Not Used
C = Input activates Color 1. Touch
activates Color 2 and Output.
D = Input activates Color 1. Touch
activates Output.
E = Input activates Color 1. Touch
activates Output. Touch with
inactive input activates Color 2.
Blank = 2 m Integral Cable
Q = Integral 4-pin M12/Euro-style
Quick Disconnect (QD) *
QP = 150 mm (5.9 in) cable with
4-pin M12/Euro-style
R = Normally
Closed
Quick Disconnect (QD) *
T = Terminal Screws
* QD model requires mating cordset
Sample Model
K30APT2GRC
Description
Normally open output state, PNP, Touch, Color 1: Green, Color 2: Red, Input activates Color 1, Touch activates Color 2 and Output, 2 m
integral cable
K30RNT2GXDQ
K30APT2BXDT
Normally closed output state, NPN, Touch, Color 1: Green, Color 2: No color, Input activates Color 1, Touch activates Output, Integral 4-pin
M12/Euro-style quick-disconnect
Normally open output state, PNP, Touch, Color 1: Blue, Color 2: No color, Input activates Color 1, Touch activates Output, Terminal screws
Wiring Diagrams
NPN
PNP
Color Key
1
3
1
3
1 = Brown
2 = White
3 = Blue
+
+
12-30V dc
–
12-30V dc
–
4 = Black
4
2
4
2
Load
Load
Job Light
Enable > 7.0V dc
Job Light
Enable < 1.0V dc
Note: Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are functionally identical.
Original Document
189827 Rev. E
3 January 2018
189827