JW
VDE
COMPACT PC BOARD
POWER RELAY
JW RELAYS
FEATURES
COMMENTS ABOUT Cd
FREE
28.6
• Miniature package with universal
terminal footprint
12.8
.504
.1.126
We have introduced Cadmium free type
products to reduce the material which is
not good for our environment. (The suffix
“F” should be added to the part number.)
(Note:The Suffix “F” is required only for 1
Form A contact type.The 1 Form C and 2
Form A and 2 Form C contact type is
originally Cadmium free, the suffix “F” is
not required.)
• High dielectric withstanding for
transient protection:
10,000 V surge in µs between coil
and contact
• Sealed construction
• Class B coil insulation types
available
• TV rated (TV-5) types available
(only for 1 Form A type)
• VDE,TÜV, SEMKO, SEV, FIMKO,TV-5
also approved
20.0
.787
mm inch
If you are still using Cadmium containing
parts, which don’t have “F” on the suffix
of the part number, please use Cadmium
free parts from now on. The life of the
Cadmium free products may be shorter
than the Cadmium containing parts
based on the load condition, so please
evaluate the Cadmium free parts with
your actual application before use.
RoHS Directive compatibility information
http://www.nais-e.com/
SPECIFICATIONS
Contact
Characteristics
Standard type
High capacity type
Standard type
High capacity type
6 cpm
1 Form A, 1 Form C,
Arrangement
Max. operating speed
1 Form A, 1 Form C
2 Form A, 2 Form C
(at rated load)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Initial insulation resistance
Between open
Min. 1,000 MΩ at 500 V DC
100 mΩ
AgSnO type
5 A 250 V AC, 10 A 250 V AC,
1,000 Vrms for 1 min.
Contact material
2
contacts
Initial
Nominal switching
capacity
Between contacts
and coil
breakdown
5,000 Vrms for 1 min.
3,000 Vrms for 1 min. (2 Form A, 2 Form C)
Min. 10,000 V
5 A 30 V DC
10 A 30 V DC
voltage*1
Max. switching
power
Between contact
sets
1,250 VA, 150 W
2,500 VA, 300 W
Rating
Max. switching
(resistive
voltage
Initial surge voltage between
contacts and coil*2
Operate time*3
250 V AC, 30 V DC
5 A 10 A
load)
Max. switching
current
Max. 15 ms
(at nominal voltage)
Min. switching
capacity#1
Release time (without diode)*3
(at nominal voltage)
100 mA, 5 V DC
Max. 5 ms
Mechanical
(at 180 cpm)
Temperature rise (at 20°C)
(at nominal voltage)
(with nominal coil voltage and
at nominal switching capacity)
5×106
1a: max. 39°C
1c, 2a, 2c: max. 55°C
(resistance method)
1a: max. 45°C
1c: max. 55°C
Expected
life (min.
Electrical (at 6 cpm)
ope.)
(resistance method)
105
(Resistive load)
Functional*4
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
Approx. 98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
Approx. 117.6 m/s2 {12 G}, 10 to 55 Hz at
double amplitude of 2.0 mm
Shock
Coil
Destructive*5
Functional*6
resistance
Nominal operating power
530 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Vibration
resistance
Destructive
Remarks
Conditions for operation, Ambient
transport and storage*7 temp.*8
(Not freezing and
* Specifications will vary with foreign standards certification ratings.
*1 Detection current: 10mA
–40°C to +85°C –40°F to +185°F
*2 Wave is standard shock voltage of 1.2 × 50µs according to JEC-212-1981
*3 Excluding contact bounce time
condensing at low
temperature)
Humidity
5 to 85% R.H.
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
Unit weight
Approx. 13 g .46 oz
*7 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT .
*8 When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.