MODEL: JR  
0: Specify  
Plug-in Signal Conditioners M-UNIT  
Note: Consult M-System for 2-wire RTD  
RTD TRANSMITTER  
(field-programmable)  
[2] OUTPUT  
Current  
Functions & Features  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Accepting direct input from an RTD and providing  
standard process signal  
• Micro-processor based  
• Field-programmable temperature range  
• Linearization  
• Burnout protection  
• Isolation up to 2000 V AC  
• Loop testing via hand-held programmer PU-2x  
• High-density mounting  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Typical Applications  
• Ideal for quick spare part  
• Power plant (2000 V AC isolation)  
50  
(1.97)  
80  
(3.15)  
[3] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
127  
(5)  
mm (inch)  
MODEL: JR–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: JR-[1][2]-[3][4]  
DC Power  
S: 12 V DC  
Specify a code from below for each of [1] through [4].  
(e.g. JR-4A-B/BL/Q)  
R: 24 V DC  
V: 48 V DC  
• Temperature range (e.g. 0 – 500°C)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS (multiple selections)  
Burnout  
blank: Upscale burnout  
/BL: Downscale burnout  
[1] INPUT RTD (2- or 3-wire)  
1: JPt 100 (JIS'89)  
Other Options  
blank: none  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)  
3: Pt 100 (JIS'89)  
/Q: Option other than the above (specify the specification)  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
4: Pt 100 (JIS'97, IEC)  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
5: Pt 50 Ω (JIS'81)  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)  
6: Ni 508.4 Ω  
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)  
JR SPECIFICATIONS  
ES-1663 Rev.10 Page 1/3  
http://www.m-system.co.jp/  

与JR-41-F/Q相关器件

型号 品牌 获取价格 描述 数据表
JR-41-G MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-G/BL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-G/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-H MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-H/BL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-H/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-J MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-J/BL MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-J/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JR-41-R MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT