AC/DC Industrial Type
160 Watts
XPiQ inc.
Intelligent Design Quality Product
JPM160 Series
CE Marked LVD
•
•
Low Cost
•
High Reliability
•
Power Factor Corrected
•
Low Ripple Noise
•
Adjustable Output
Specification
Input
General
AC Input Voltage
Input Frequency
DC Input Voltage
Power Factor
Input Current
Inrush Current
Set-Up time
•
•
•
•
•
•
•
•
85-264 VAC
Efficiency
•
•
•
•
See Table
47-63 Hz
MTBF
100,000 hrs min
<2 mA at 240 VAC
120-370 VDC
Leakage Current
Isolation Voltage
0.98 at 115 VAC, 0.96 at 230 VAC
2.8 A max at 115 VAC
40 A at 230 VAC cold start
600 ms
3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Size
•
•
199 x 99 x 50mm
800 grams
Weight
Rise Time
30 ms
Environmental
Output
Output Voltage
Operating
•
-10 °C to +60 °C
(see derating curves)
•
•
•
3.3 V to 48 V single outputs
160 Watts, see table
+10%, -5%
Temperature
Output Power
Cooling
•
•
Internal fan
Output Voltage
Adjustment
Humidity
20-90% RH non condensing
Storage Temperature • -20 °C to +85 °C
Minimum Load
Tolerance
•
•
•
•
•
•
0 minimum load required
2% max
Shock & Vibration
•
10-500 Hz 2G 10 min/cycle
for 60 min each axis
Line Regulation
Load Regulation
Ripple & Noise
Transient Response
0.5%
1% max, see table
100 mV typical, see table
EMC & Safety
Safety Approvals
•
•
•
UL1950, CSA C22.2 No. 950
per cUL, EN60950, CE Mark LVD
5% max deviation, 500 µs
recovery time for a 50% load change
EMI/EMC
Meets EN61000-3-2, -3, ENV50204,
CISPR22 (EN55022) Class B
Temperature
Coefficient
•
0.05%/°C
Immunity & Surge
Meets EN61000-4-2, -3, -4,
-5, -6 , -8, -11
Hold Up Time
•
•
20 ms minimum at 230 VAC
110-135 %
Overvoltage
Protection
Overcurrent
Protection
•
•
130-170%, constant current
auto restart
Overtemperature
Protection
Shutdown at +95 °C 5 °C
with auto recovery
•
•