Plug-in Signal Conditioners M-UNIT

JPA2-74-S 数据手册

 浏览型号JPA2-74-S的Datasheet PDF文件第2页浏览型号JPA2-74-S的Datasheet PDF文件第3页浏览型号JPA2-74-S的Datasheet PDF文件第4页浏览型号JPA2-74-S的Datasheet PDF文件第5页 
MODEL: JPA2  
Factory Setting  
Plug-in Signal Conditioners M-UNIT  
Input type  
Pulse amplitude  
Pulse sensing  
Open collector  
----  
DC coupled  
FREQUENCY TRANSMITTER  
(field-programmable; built-in excitation)  
Functions & Features  
Low  
Detecting level  
2V *1  
0 – 1 kHz  
0 Hz  
Frequency range  
Input zero frequency  
Input span frequency  
Low-end cutout  
• Converts the output from a pulse-type transducer into a  
standard process signal  
1 kHz  
-15%  
• Built-in excitation  
Low-end cutout deadband  
Alarm setpoint  
Alarm deadband  
1%  
100%  
1.00%  
High alarm  
• Field-selectable input type and range: Open collector,  
mechanical contact, voltage pulse or two-wire current pulse  
• Isolation up to 2000 V AC  
Alarm mode  
Non-uniform pulse  
compensation  
Linearization  
• High-density mounting  
1 (no compensation)  
Without  
Typical Applications  
*1. Detecting voltage in the internal circuit  
• Positive displacement flowmeters, turbine flowmeters and  
vortex flowmeters  
INPUT – Field-selectable  
Open collector  
• Measuring rotation speed of a machine generating dry  
contact signals  
Mechanical contact  
Voltage pulse  
50  
(1.97)  
Two-wire current pulse  
80  
(3.15)  
[1] EXCITATION  
1: 5 V DC @ 120 mA  
4: 12 V DC @ 60 mA  
7: 24 V DC @ 25 mA  
136  
(5.35)  
mm (inch)  
[2] OUTPUT  
Current  
MODEL: JPA2–[1][2]–[3][4]  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
ORDERING INFORMATION  
• Code number: JPA2-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. JPA2-76-K/Q)  
• Special output range (For codes Z & 0)  
• Use Ordering Information Sheet (No. ESU-1572). Factory  
setting (indicated below) will be used if not otherwise  
specified.  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
JPA2 SPECIFICATIONS  
ES-1572 Rev.9 Page 1/5  
http://www.m-system.co.jp/  

与JPA2-74-S相关器件

型号 品牌 获取价格 描述 数据表
JPA2-74-S/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74-V MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74-V/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-K MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-K/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-P MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-P/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-R MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-R/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA2-74W-S MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT