5秒后页面跳转
JPA-25B/Q PDF预览

JPA-25B/Q

更新时间: 2024-11-12 02:21:23
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 105K
描述
Plug-in Signal Conditioners M-UNIT

JPA-25B/Q 数据手册

 浏览型号JPA-25B/Q的Datasheet PDF文件第2页浏览型号JPA-25B/Q的Datasheet PDF文件第3页 
MODEL: JPA  
Plug-in Signal Conditioners M-UNIT  
[1] INPUT  
1: Open collector (Excitation: 12 V @ 30 mA)  
2: Voltage pulse (Excitation: 12 V @ 30 mA)  
3: Mechanical contact (Excitation: 12 V @ 30 mA)  
FREQUENCY TRANSMITTER  
(field-programmable)  
Functions & Features  
• Converting the output from a pulse-type transducer into  
standard process signal  
[2] OUTPUT  
Current  
• Micro-processor based  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Field-programmable frequency range  
• Linearization available for flow compensation  
• Averaging non-uniform pulses  
• Excitation  
• Isolation up to 2000 V AC  
• Loop testing via hand-held programmer PU-2x  
• High-density mounting  
Typical Applications  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Positive displacement flowmeters, turbine flowmeters and  
vortex flowmeters  
• Proximity switches  
• Oval flowmeters  
50  
(1.97)  
80  
(3.15)  
[3] POWER INPUT  
AC Power  
127  
(5)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
mm (inch)  
MODEL: JPA–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: JPA-[1][2]-[3][4]  
DC Power  
S: 12 V DC  
Specify a code from below for each of [1] through [4].  
(e.g. JPA-23-B/Q)  
R: 24 V DC  
V: 48 V DC  
• Frequency range (e.g. 0 – 152.3 Hz)  
• Special output ranges (For codes Z & 0)  
• Linearization data (max. 16 points)  
Use Ordering Information Sheet (No. ESU-1673) to specify  
linearization data when the I/O signals are non-linear.  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
Note: Consult factory on applications with a sensor handling  
periodically (& quickly) changing frequency (e.g. oval  
flowmeter).  
JPA SPECIFICATIONS  
ES-1673 Rev.12 Page 1/3  
http://www.m-system.co.jp/  

与JPA-25B/Q相关器件

型号 品牌 获取价格 描述 数据表
JPA-25C MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25C/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25D MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25D/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25F MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25F/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25G MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25G/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25H MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JPA-25H/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT