JFS Series
Single Output Industrial Power Supplies
Features
u Power factor Corrected
u Wide range output adjustment
u Single wire current share
u Input transient protection
u UL508 Industrial Controls Approval
u Factory Mutual Approval (Class 1, Div 2)
u 5 Year Warranty
u EN61000-4 Input Transient
Specifications
Model
JFS0500
JFS0750
JFS1000
JFS1500
JFS2000
AC Input Voltage
-
-
85-265VAC (170-265VAC JFS2000), 47-63Hz
120-330VDC (240-330VDC for JFS2000)
DC Input Voltage Range
Input Current (typ@110VAC)
Inrush Current (110 / 220VAC)
Efficiency (typ@110VAC)
Power Factor
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Transient Reponse
Remote Sense
A rms
A
%
-
-
V
ms
-
6
9
12
20
12(1)
- / 70
82(2)
35 / 70
75
Meets EN61000-3-2 (0.99 typical)
<110% (auto recovery)
24V models set at 30V, 48V models set at 60V (auto recovery)
16
For 25% load change, recovers to regulation within 5ms
Compenstates for 0.25V drop per leg
With either external Resistor or Voltage
Low = OFF, Open = ON
-
-
-
Remote Adjust
Remote On / Off
Signals & Indicators
Parallel Connection
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
-
-
°C
°C
%RH
-
Open Collector AC Fail and DC Good, Green LED
Single wire current share
-20 to +70°C, derate linearly to 50% load from 50°C (30 min warm up at -20°C)
-40 to +85
10 - 90
Internal fan
Withstand Voltage
Vibration
-
-
Input - Ground 2kVAC, Input - Output 3kVAC, Output - Ground 500VDC
Per IEC68-2-6
Shock
-
-
-
Per IEC68-2-27
Safety Agency Approvals
Conducted & Radiated EMI
Weight (Net / Shipping)
Size (WxHxD)
UL508, UL60950, CSA22.2 No.60950, EN60950, FM3611 & CE Mark
EN55022 Class A, FCC Docket 20780 Part 15, subpartJ, Class A
lbs
mm
-
6 / 7
7 / 8
9 / 10
See output line drawings
5 years
Warranty
Notes: (Consult Installation Manual for detailed specifications, test methods and application notes)
(1) At 220VAC
(2) At 170VAC
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1