2:1 Input Range

JCK1524D03 数据手册

 浏览型号JCK1524D03的Datasheet PDF文件第2页 
xppower.com  
15 Watts  
JCK Series  
2:1 Input Range  
Industry Standard Package  
1500 VDC Isolation  
Continuous Short Circuit Protection  
High Efficiency ꢀ up to 89%  
ꢀ40 °C to +100 °C Operating Temperature  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage Range  
• 12 V (9-18 VDC)  
Efficiency  
• See table  
24 V (18-36 VDC)  
48 V (36-75 VDC)  
• See table  
Isolation Voltage  
• 1600 VDC Input to Output,  
optional 3500 V (see note 4)  
1600 VDC Input to Case  
Input Current  
1600 VDC Output to Case  
Input Reflected  
Ripple Current  
• 20 mA rms through 12 µH inductor,  
5 Hz to 20 MHz  
Isolation Capacitance • 1200 pF typical  
9
Under Voltage Lockout • 12 V models On 8.6 V, Off 7.9 V typical  
24 V models On 17.8 V, Off 16 V typical  
Isolation Resistance  
Switching Frequency  
Power Density  
MTBF  
• 10 Ω min  
• 300 kHz typical  
48 V models On 33.5 V, Off 30.5 V typical  
3
• 18.75 W/in  
Input Surge  
• 12 V models 30 VDC for 100 ms  
24 V models 50 VDC for 100 ms  
48 V models 100 VDC for 100 ms  
• >1.1 MHrs to MIL-HDBK-217F  
at 25 şC, GB  
Environmental  
Output  
Operating Temperature • -40 °C to +100 °C, derate from 100% load  
Output Voltage  
Minimum Load  
Line Regulation  
Load Regulation  
• See table  
• No minimum load required  
at +70 °C to 0% load at +100 °C  
• +100 °C max  
Case Temperature  
0.5% max  
0.5% max for single and dual outputs  
except 0.8% for D03 versions  
Storage Temperature • -40 °C to +125 °C  
Cooling  
• Convection-cooled  
• Up to 95% RH, non-condensing  
Operating Humidity  
Cross Regulation  
5% max on dual output models  
(see note 2)  
EMC  
Setpoint Accuracy  
Start Up Delay  
1.0% max  
Emissions  
• EN55022, Class A conducted  
& radiated with external components,  
see application note  
• EN61000-4-2, 8 kV air, 6 kV contact,  
Perf Criteria A  
• EN61000-4-3 10 V/m, Perf Criteria A  
• EN61000-4-4 level 3, Perf Criteria B*  
• EN61000-4-5 level 2, Perf Criteria B*  
• EN61000-4-6 10 V/rms,Perf Criteria A  
• EN61000-4-8 1 A/m, Perf Criteria A  
• <20 ms  
• <5 ms  
• 75 mV pk-pk max (see note 3)  
Start Up Rise Time  
Ripple & Noise  
ESD Immunity  
Transient Response  
3% max deviation, recovery to within 1%  
in 250 µs for a 25% load change  
Radiated Immunity  
EFT/Burst  
Temperature  
Coefficient  
• 0.02%/°C  
Surge  
Overload Protection  
• >140% of full load at nominal input  
Conducted Immunity  
Magnetic Field  
Short Circuit Protection • Trip & restart (hiccup mode) with  
auto recovery  
Maximum Capacitive  
Load  
• See table  
*External input capacitor required 220 µF/100 V.  

与JCK1524D03相关器件

型号 品牌 获取价格 描述 数据表
JCK1524D05 XPPOWER

获取价格

2:1 Input Range
JCK1524D12 XPPOWER

获取价格

2:1 Input Range
JCK1524D15 XPPOWER

获取价格

2:1 Input Range
JCK1524S05 XPPOWER

获取价格

2:1 Input Range
JCK1524S12 XPPOWER

获取价格

2:1 Input Range
JCK1524S15 XPPOWER

获取价格

2:1 Input Range
JCK1524S3V3 XPPOWER

获取价格

2:1 Input Range
JCK1548D03 XPPOWER

获取价格

2:1 Input Range
JCK1548D05 XPPOWER

获取价格

2:1 Input Range
JCK1548D12 XPPOWER

获取价格

2:1 Input Range