MODEL: JAPD2
RNG4 10 Hz: 0 – 20 Hz
RNG5 1 Hz: 0 – 2 Hz
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
RNG6 100 mHz: 0 – 200 mHz
Min. span: 10 % of available frequency range
Duty ratio: 50 %
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
■ Open Collector: 50 V DC @50 mA (resistive load)
Saturation voltage: 0.6 V DC
■ Voltage Pulse
H level: Rating 5, 12 or 24 V ±10 %
L level: ≤ 0.5 V
GENERAL SPECIFICATIONS
Construction: Plug-in
Load resistance: ≥ 1 kΩ (5 V), ≥ 2.4 kΩ (12 V), ≥ 4.8 kΩ (24
V)
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
■ Noncontact AC/DC Switch: 120 V AC or 120 V DC @200
mA (resistive load)
ON resistance: 3 Ω max.
Housing material: Flame-resistant resin (black)
Isolation: Input to alarm output to output to power
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Alarm output: Turns on when the input goes above (high) or
below (low) setpoint
Rise time: 5 msec.
Sink time: 3 msec.
■ RS-422 Line Driver Pulse
Transmitter: Conforms to RS-422
■ Relay Contact:
100 V AC @ 1 A (cos ø = 1)
Alarm setpoint: -5 – +105 %
120 V AC @ 1 A (cos ø = 1)
Alarm deadband (hysteresis): 0 – 20 %
Output monitor LED: Red LED turns on when the output is
ON or high.
240 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 1 A (resistive load)
Maximum switching voltage: 380 V AC or 125 V DC
Maximum switching power: 120 VA or 30 W
Minimum load: 5 V DC @ 10 mA
Power ON delay time: 2.0 to 1000.0 sec.
Software programming: Programming Unit (model: PU-2x);
(Refer to the users manual of JXCON for the adjustments
configurable with JXCON)
Mechanical life: 5 x 10 cycles (300 cycle/minute)
7
• Output frequency (zero and span)
• Alarm
INSTALLATION
Power input
• Power ON delay time
•AC: Operational voltage range 85 – 264 V, 47 - 66 Hz;
Approx. 3.2 VA at 100 V
• Others
Approx. 5.1 VA at 200 V
INPUT SPECIFICATIONS
■ DC Current:
Approx. 6.9 VA at 264 V
•DC: Operational voltage range: rating ±10 %, or 85 – 150 V
for 110 V rating (ripple 10 % p-p max.)
Approx. 2.5 W (100 mA at 24 V)
Shunt resistor attached to the input terminals (0.5 W)
Specify input resistance value for code Z.
■ DC Voltage: -300 – +300 V DC
Minimum span: 10 mV
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Offset: Max. 1.5 times span
Input resistance
Weight: 280 g (0.62 lb)
Span 10 – 100 mV : ≥ 10 kΩ
Span 0.1 – 1 V : ≥ 100 kΩ
Span ≥ 1 V : ≥ 1 MΩ
OUTPUT SPECIFICATIONS
Frequency range: 100 mHz to 10 kHz (RNG1 to RNG6)
[ Range name : Available frequency ]
RNG1 10 kHz: 0 – 20 kHz
RNG2 1 kHz: 0 – 2 kHz
RNG3 100 Hz: 0 – 200 Hz
JAPD2 SPECIFICATIONS
ES-1571 Rev.6 Page 2/4
http://www.m-system.co.jp/