MODEL: JAPD2  
Plug-in Signal Conditioners M-UNIT  
[1] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
DC/FREQUENCY CONVERTER  
(field-programmable)  
Functions & Features  
• Providing a pulse rate output in proportion to DC input  
signal  
• Parameters are field-programmable via hand-held  
programmer PU-2x  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
• Monitoring & control of power supply system  
• Quick countermeasure applicable even in failure or in  
sudden voltage change  
50  
(1.97)  
80  
(3.15)  
[2] OUTPUT  
A: Open collector  
M: 5 V pulse  
127  
(5)  
mm (inch)  
N: 12 V pulse  
P: 24 V pulse  
J: RS-422 line driver pulse  
R: AC/DC switch  
MODEL: JAPD2–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: JAPD2–[1][2]–[3][4]  
Specify a code from below for each of[1] through [4].  
(e.g. JAPD2-6A-S/Q)  
[3] POWER INPUT  
AC Power  
M2: 100 – 240 V AC  
DC Power  
• Special input range (For codes Z & 0)  
• Use Ordering Information Sheet (No. ESU-1571).  
Default setting (table below) will be used if not otherwise  
specified.  
S: 12 V DC  
R: 24 V DC  
P: 110 V DC  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS  
blank: none  
ITEM  
DEFAULT  
/Q: With options (specify the specification)  
Output zero frequency  
Output span frequency  
0 kHz  
1 kHz  
(10 Hz for output code R)  
100.00%  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Alarm setpoint  
Alarm hysteresis  
Alarm mode  
1.00%  
No alarm  
/C02: Polyurethane coating  
Power ON-delay time  
3.0 sec.  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
JAPD2 SPECIFICATIONS  
ES-1571 Rev.6 Page 1/4  
http://www.m-system.co.jp/  

与JAPD2-0N-R/Q相关器件

型号 品牌 获取价格 描述 数据表
JAPD2-0N-S MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0N-S/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0-P MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0-P/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-M2 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-M2/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-P MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-P/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-R MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JAPD2-0P-R/Q MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT