APPLICABLE STANDARD IEC 61076-3-124
Operating Temperature
Range
Storage Temperature
Range
-40C to +85C
(note1,2)
-30C to +60C
(95%RH max)
(95%RH max)
(note1)
RATING
1.5 A/pin (all pin)
Voltage
Current
50 V AC / 60 V DC
3 A/pin (pin No.1,2,6,7)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Marking
Examined visually and with a measuring instrument.
Confirmed visually.
According to drawing.
According to drawing.
X
X
X
X
ELECTRIC CHARACTERISTICS
Contact : 30 m max. (note3)
Shield : 100 m max. (note3)
Contact Resistance
Measured at 100 mA max (DC or 1000 Hz).
X
-
Insulation Resistance
Voltage Proof
Measured at 500 V DC.
500 M min.
X
X
-
-
500 V DC applied for 1 min. Current leakage 2mA max.
Measured in the range of 1 to 500 MHz.
No breakdown.
2
△
Insertion Loss
0.02 √(f) dB max.
(Whenever the formula results in a value less than
0.1 dB, the requirement shall revert to 0.1 dB.)
X
X
X
-
-
-
Return Loss
Measured in the range of 1 to 500 MHz.
Measured in the range of 1 to 500 MHz.
68 – 20log(f) dB min.
(Whenever the formula results in a value greater than
30 dB, the requirement shall revert to 30 dB.)
Near end Crosstalk
94 – 20log(f) dB min. (1MHz to 250MHz)
46.04 – 30log(f/250) dB min. (250MHz to 500MHz)
(Whenever the formula results in a value greater than
75 dB, the requirement shall revert to 75 dB.)
Far end crosstalk
Measured in the range of 1 to 500 MHz.
83.1 – 20log(f) dB min.
(Whenever the formula results in a value greater than
75 dB, the requirement shall revert to 75 dB.)
X
X
X
X
-
-
-
-
Transverse Conversion Loss Measured in the range of 1 to 500 MHz.
68 – 20log(f) dB min.
(Whenever the formula results in a value greater than
50 dB, the requirement shall revert to 50 dB.)
Transverse Conversion
Transfer Loss
Measured in the range of 1 to 500 MHz.
68 – 20log(f) dB min.
(Whenever the formula results in a value greater than
50 dB, the requirement shall revert to 50 dB.)
MECHANICAL CHARACTERISTICS
Insertion force
25 N max.
25 N max.
Insertion and Withdrawal
A maximum rate of 50 mm/min.
Withdrawal force
Forces
Measured by applicable connector.
5000 times insertions and extractions.
1) Resistance:
Mechanical Operation
Contact : 80 m max. (note3)
X
-
Shield : 100 m max. (note3)
Mating speed : 10 mm/s max.
Rest : 5s, min.(unmated)
2) No damage, cracks or looseness of parts.
Note
1. Non-condensing. 2. The operation temperature includes the temperature rise by current carrying
3. The cable conductor resistance is not considered.
4. Electrical characteristics are applicable to the contacts and shield except for contacts No. 3 and 8.
COUNT
7
DESCRIPTION OF REVISIONS
DIS-E-00016077
DESIGNED
MT.YASUDA
CHECKED
DATE
KI.KAGOTANI
20240419
2
△
APPROVED
CHECKED
DESIGNED
MN.KENJO
KI.NAGANUMA
MT.YASUDA
20191209
20191209
20191209
REMARK
DRAWN
YK.MITSUISHI
20191209
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129987-01-00
IX40G-A-10S-CVL1(7.0)(01)
1/
PART NO.
CODE NO.
SPECIFICATION SHEET
2
△
3
HIROSE ELECTRIC CO., LTD.
CL0251-0075-0-01
FORM HD0011-2-1