ISL75052SEH, ISL73052SEH
Ordering Information
RADIATION
ORDERING SMD NUMBER
(Note 2)
PART NUMBER
(Note 1)
HARDNESS
(Total Ionizing Dose) TEMP RANGE (°C)
PACKAGE
(RoHS Compliant)
PKG DWG. #
K16.E
5962R1322001VXC
ISL75052SEHVFE
ISL75052SEHVX (Note 3)
ISL75052SEHX/SAMPLE (Notes 3, 4) N/A
HDR to 100krad(Si)
LDR to 50krad(Si)
-55 to +125
-55 to +125
-55 to +125
-55 to +125
-55 to +125
-55 to +125
-55 to +125
-55 to +125
16 Ld CDFP
Die
5962R1322001V9A
N/A
Die Sample
16 Ld CDFP
16 Ld CDFP
Die
N/A
ISL75052SEHFE/PROTO (Note 4)
ISL73052SEHVFE
N/A
K16.E
K16.E
5962L1322002VXC
LDR to 50krad(Si)
5962L1322002V9A
ISL73052SEHVX (Note 3)
N/A
N/A
ISL73052SEHX/SAMPLE (Notes 3, 4) N/A
Die Sample
16 Ld CDFP
ISL73052SEHFE/PROTO (Note 4)
ISL75052SEHEVAL1Z (Note 5)
N/A
K16.E
N/A
Evaluation Board
NOTES:
1. These Pb-free Hermetic packaged products employ 100% Au plate - e4 termination finish, which is RoHS compliant and compatible with both SnPb
and Pb-free soldering operations.
2. Specifications for Rad Hard QML devices are controlled by the Defense Logistics Agency Land and Maritime (DLA). The SMD numbers listed must be
used when ordering.
3. Die product tested at T = + 25°C. The wafer probe test includes functional and parametric testing sufficient to make the die capable of meeting the
A
electrical performance outlined in “Electrical Specifications” on page 5.
4. The /PROTO and /SAMPLE are not rated or certified for Total Ionizing Dose (TID) or Single Event Effect (SEE) immunity. These parts are intended for
engineering evaluation purposes only. The /PROTO parts meet the electrical limits and conditions across temperature specified in the DLA SMD and
are in the same form and fit as the qualified device. The /SAMPLE parts are capable of meeting the electrical limits and conditions specified in the
DLA SMD. The /SAMPLE parts do not receive 100% screening across temperature to the DLA SMD electrical limits. These part types do not come
with a Certificate of Conformance because they are not DLA qualified devices.
5. Evaluation boards use the /PROTO parts and /PROTO parts are not rated or certified for Total Ionizing Dose (TID) or Single Event Effect (SEE) immunity.
FN8456 Rev.8.01
Mar 19, 2020
Page 3 of 20