60W Isolated Dual Output Switching Power Supply
ID-60B
Features :
Isolated output & GND for CH1,CH2
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Coolig by free air convection
100% full load burn-in test
Fixed switching frequency at 54KHz
2 years warranty
SPECIFICATION
MODEL
ID-60B
OUTPUT NUMBER
CH1
5V
CH2
DC VOLTAGE
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
3A
1.8A
0.3 ~ 6A
58W
0.2 ~ 2.2A
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
240mVp-p
OUTPUT
CH1 : 4.75 ~ 5.5V
8.0%
1.0%
5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
0.5%
0.5%
300ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
90ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
76%
10ms/115VAC at full load
120 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
INPUT
2A/115VAC
1A/230VAC
COLD START 25A/115VAC
<1mA / 240VAC
45A/230VAC
105% ~ 150% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (-10 80% load, 60 60% load)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
SAFETY &
EMC
(Note 4)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
320.9K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.55Kg; 24pcs/13.9Kg/0.75CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ID-60B-SPEC 2005-09-13