INNOVATION
SOLUTIONS
SUPPORT
RELIABILITY
• Lifetime Warranty
• UL508 approved
• SEMI F47 Compliant (high line AC)
• Universal Input (85 - 265VAC)
• High Efficiency
• RoHS Compliant Design
Key Market Segments & Applications
Factory Automation
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
HWS Series
Chemical Processing, Robots
Test & Measurement Burn-in & Test, Automated
Single Output Industrial
Power Supplies
Automated Service
Test, Instrumentation,
Measurement, Detection
HWS Features and Benefits
Features
Benefits
• Lower Cost of Ownership
• Easier System Cooling
• Supports Global Use
• Lifetime Warranty
• High Efficiency
• Wide Range AC Input
Specifications
MODELS
ITEMS
HWS15
0.4 / 0.2
HWS30
HWS50
HWS100
HWS150
1.9 / 0.95
Input Voltage range
Input Current (Typ) (1)
Inrush Current 100/200VAC
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
0.8 / 0.4
A
A
0.7 / 0.35
14 / 28
Meets EN61000-3-2
<0.02%/oC
>104%
1.3 / 0.65
-
V
ms
mA
Yes (See page 2)
20
<0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC)
No Yes
Indicator
Green LED = ON
Operating Temp. (no cover)
Storage Temperature
Humidity (non condensing)
Cooling
-10C to +70C, derate linearly to 20% load from 50C to 70C
-30 to +85C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1m/s2
Safety Agency Approvals
Line Dip
Conducted & Radiated
Immunity
-UL60950-1, CSA60950-1, EN60950-1, EN50178, Built to meet UL508 CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
EMI
IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 4), -5(Level 3,4), -6(Level 3), -8(Level4, -11
Weight (Typ)
g
180
220
280
450
500
Size (WxHxD)
mm
26.5x82x80
26.5x82x95
26.5x82x120
28x82x160
37x82x160
Warranty
Lifetime Warranty (See Lambda’s terms & conditions)
Notes:
(1) 100/200VAC
See website for HWS/ME medical EN/UL60601-1 approved models
and HWS/HD heavy duty / harsh environment models with -40 degree C startup
HWS SERIES
1