描述
Current Transducers

HTB50-P_07 数据手册

 浏览型号HTB50-P_07的Datasheet PDF文件第2页 
Current Transducers HTB 50..400-P  
and HTB 50..100-TP  
IPN DC = ± 50 .. 400 A  
For the electronic measurement of currents: DC, AC, pulsed, mixed,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
Electrical data  
Primary continuous  
direct current  
(nominal) IPN DC (A)  
Primary current,  
measuring range  
IPM (A)  
Type  
RoHS since  
date code  
Features  
± 50  
± 150  
± 300  
± 500  
± 600  
± 600  
HTB 50-P, HTB 50-TP1)  
HTB 100-P, HTB 100-TP1)  
HTB 200-P  
HTB 300-P  
HTB 400-P  
46104, 46166  
45178, 46183  
45198  
45225  
46224  
± 100  
± 200  
± 300  
± 400  
· Hall effect measuring principle  
· Galvanic isolation between primary  
and secondary circuit  
· Isolationvoltage2500V  
· Low power consumption  
· Wide power supply: ±12V to ±15V  
· Primary bus bar option for 50A and  
100A version for ease of connection  
VC  
Supply voltage (± 5 %)2)  
Current consumption  
± 12 .. 15  
V
IC  
< ± 15  
2.5  
mA  
kV  
Vd  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Isolation resistance @ 500 VDC  
RIS  
VOUT  
ROUT  
RL  
> 500  
MW  
V
Output voltage (Analog) @ ± IPN DC, RL = 10 kW, TA = 25°C ± 4  
Output internal resistance  
Load resistance  
100  
W
Advantages  
³ 10  
kW  
· Small size and space saving  
· Only one design for wide current  
ratings range  
Accuracy - Dynamic performance data  
X
Accuracy @ IPN DC, TA = 25°C (excluding offset)  
< ± 1 % of IPN DC  
< ± 1 % of IPN DC  
· High immunity to external  
interference.  
e
Linearity error (0 .. ± IPN DC)  
L
VOE  
VOH  
Electrical offset voltage, TA = 25°C  
Hysteresis offset voltage @ IP = 0;  
after an excursion of 1 x IPN DC  
< ± 30  
mV  
Applications  
< ± 1 % of IPN DC  
TCVOE  
Temperature coefficient of VOE HTB 50-(T)P  
< ± 2.0 mV/K  
· AC variable speed drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
· Switched Mode Power Supplies  
(SMPS)  
· Power supplies for welding  
applications.  
HTB 100-(T)P..400-P < ± 1.0 mV/K  
TCVOUT  
tr  
Temperature coefficient of VOUT (% of reading)  
< ± 0.1  
< 3  
%/K  
ms  
Response time to 90% of IPN DC  
Frequency bandwidth (0..-3 dB) 3)  
BW  
DC .. 50  
kHz  
General data  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
Mass (-TP version)  
- 20 .. + 80 °C  
- 25 .. + 85 °C  
< 30 (< 36)  
g
Applicationdomain  
Standards  
EN 50178: 1997  
· Industrial  
2 pins of Ø2mm diameter are available on transducer  
for PCB soldering.  
Notes :  
1)  
-TP version is equipped with a primary bus bar.  
2) Operating at ±12V £ Vc < ±15V will reduce measuring range.  
3) Derating is needed to avoid excessive core heating at high frequency.  
Page 1/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
070313/11  
www.lem.com  

与HTB50-P_07相关器件

型号 品牌 获取价格 描述 数据表
HTB50-SP5 LEM

获取价格

Current Transducers
HTB50-TP LEM

获取价格

Current Transducers HTB 50~400-P and HTB 50~100-TP
HTB50-TP/SP5 LEM

获取价格

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
HTB50-TP1 LEM

获取价格

Current Transducers
HTB-521 COOPER

获取价格

Analog Circuit
HTB-52I ETC

获取价格

HTB Panel Mount Series
HTB-52I2 ETC

获取价格

HTB Panel Mount Series
HTB-52I4 ETC

获取价格

HTB Panel Mount Series
HTB-52I6 ETC

获取价格

HTB Panel Mount Series
HTB-52I8 ETC

获取价格

HTB Panel Mount Series