HS-390RH-T
Data Sheet
July 1999
File Number 4604.1
Radiation Hardened
Features
CMOS Dual SPDT Analog Switch
• QML Class T, Per MIL-PRF-38535
Intersil’s Satellite Applications FlowTM (SAF) devices are fully
tested and guaranteed to 100kRAD total dose. This QML
Class T device is processed to a standard flow intended to
meet the cost and shorter lead-time needs of large volume
satellite manufacturers, while maintaining a high level of
reliability.
• Radiation Performance
5
- Gamma Dose (γ) 1 x 10 RAD(Si)
- No Latch-Up, Dielectrically Isolated Device Islands
• Pin for Pin Compatible with Intersil HI-390 Series Analog
Switches
• Analog Signal Range 15V
The HS-390RH-T analog switch is a monolithic device
fabricated using Radiation Hardened CMOS technology and
the Intersil dielectric isolation process for latch-up free
operation. Improved total dose hardness is obtained by
layout (thin oxide tabs extending to a channel stop) and
processing (hardened gate oxide). These switches offer low-
resistance switching performance for analog voltages up to
the supply rails. “ON” resistance is low and stays reasonably
constant over the full range of operating voltage and current.
“ON” resistance also stays reasonably constant when
exposed to radiation, being typically 30Ω pre-rad and 35Ω
post 100kRAD(Si). Break-before-make switching is
controlled by 5V digital inputs.
• Low Leakage . . . . . . . . . . . . . . . . 100nA (Max, Post Rad)
• Low r
. . . . . . . . . . . . . . . . . . . . . . 60Ω (Max, Post Rad)
ON
• Low Operating Power . . . . . . . . . . 100µA (Max, Post Rad)
Pinouts
HS1-390RH (SBDIP), CDIP2-T16
TOP VIEW
D1
NC
D3
S3
S4
D4
NC
D2
1
2
3
4
5
6
7
8
16 S1
15
14
13
12
11
10
9
IN1
V-
GND
NC
V+
Specifications
IN2
S2
Specifications for Rad Hard QML devices are controlled by
the Defense Supply Center in Columbus (DSCC). The SMD
numbers listed below must be used when ordering.
HS9-390RH (FLATPACK), CDFP4-F16
Detailed Electrical Specifications for the HS-390RH-T
are contained in SMD 5962-95813. A “hot-link” is provided
from our website for downloading.
TOP VIEW
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
S1
D1
NC
D3
S3
S4
D4
NC
D2
www.intersil.com/spacedefense/newsafclasst.asp
IN1
V-
Intersil’s Quality Management Plan (QM Plan), listing all
Class T screening operations, is also available on our
website.
GND
NC
V+
www.intersil.com/quality/manuals.asp
IN2
S2
Ordering Information
TEMP.
Functional Diagram
ORDERING
NUMBER
PART
NUMBER
RANGE
o
( C)
N
P
5962R9581303TEC
5962R9581303TYC
HS1-390RH-T
HS9-390RH-T
-55 to 125
-55 to 125
IN
D
NOTE: Minimum order quantity for -T is 150 units through
distribution, or 450 units direct.
TRUTH TABLE
SW1 SW2
OFF
LOGIC
SW3 SW4
ON
0
1
ON
OFF
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 1999