150W Single Output with PFC Function
HRPG-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 88%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
1U low profile 38mm
Built-in remote ON-OFF control
Stand by 5V@0.3A
Built-in remote sense function
No load power consumption<0.5W (Note.6)
5 years warranty
SPECIFICATION
MODEL
HRPG-150-3.3 HRPG-150-5 HRPG-150-7.5 HRPG-150-12 HRPG-150-15 HRPG-150-24 HRPG-150-36 HRPG-150-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
30A
26A
20A
13A
10A
6.5A
4.3A
3.3A
0 ~ 30A
99W
0 ~ 26A
130W
80mVp-p
4.3 ~ 5.8V
2.5%
0 ~ 20A
150W
100mVp-p
6.8 ~ 9V
2.5%
0 ~ 13A
156W
120mVp-p
0 ~ 10A
150W
150mVp-p
0 ~ 6.5A
156W
0 ~ 4.3A
154.8W
200mVp-p
0 ~ 3.3A
158.4W
240mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.5%
150mVp-p
OUTPUT
2.8 ~ 3.8V
10.2 ~ 13.8V 13.5 ~ 18V
21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
1.5%
0.3%
0.5%
1.5%
0.3%
0.5%
1.5%
0.2%
0.5%
1.5%
0.2%
0.5%
1.5%
0.2%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
0.5%
0.5%
1.0%
1.0%
3000ms, 50ms/230VAC
3000ms, 50ms/115VAC at full load
16ms/115VAC at full load
120 ~ 370VDC
16ms/230VAC
Note.5 85 ~ 264VAC
47 ~ 63Hz
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95/230VAC
PF>0.99/115VAC at full load
86% 87%
INPUT
78.5%
84%
87%
87%
88%
88%
2.3A/115VAC
35A/115VAC
<1mA / 240VAC
1.3A/230VAC
70A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
OVERLOAD
3.96 ~ 4.62V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
95 (3.3V ~ 7.5V) , 85 (12V ~ 48V) (TSW1 : detect on heatsink Q1 of power transistor)
105 (3.3V ~ 7.5V), 100 (12V ~ 48V) (TSW2 : detect on heatsink HS4 of power transistor)
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
-40 ~ +70 (Refer to "Derating Curve")
5V STANDBY
FUNCTION
REMOTE CONTROL
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50
ENVIRONMENT
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
213.4K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
MTBF
OTHERS
NOTE
DIMENSION
PACKING
0.63Kg; 24pcs/16Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. No load power consumption<0.5W when RC- & RC+ (CN100 pin5,6) 0 ~ 8V or short.
File Name:HRPG-150-SPEC 2011-06-21